Error Messages in Windows NT
Controller A1 PCMCIA 10 Troubleshooting 51
Error message: CAPI.DLL, CAPI20.DLL or CAPI2032.DLL not
found.
Possible cause: The DLL files have been renamed or removed
from the WINDOWS\SYSTEM directory.
Solution: Perform a complete new installation of the AVM
ISDN-Controller A1 PCMCIA to replace the missing files.
Error message: Incorrect CAPI driver loaded.
Possible cause: The PC tried to use a non-AVM CAPI with the
AVM ISDN-Controller A1 PCMCIA.
Solution: Repeat the driver software installation for the AVM
ISDN-Controller A1 PCMCIA.
Error message: Active and passive controllers cannot be
operated simultaneously.
Possible cause: You attempted to install another passive or
an active controller (e.g. B1 PCMCIA) in the same system as
your (passive) AVM ISDN-Controller A1 PCMCIA.
Solution: Simultaneous operation of multiple passive ISDN-
Controllers or simultaneous operation of active and passive
ISDN-Controllers is not possible.
Error Messages in Windows NT
Error message: Controller-xx with I/O address <xxx> not
found.
Solution: Insert the controller A1 PCMCIA into the PCMCIA
slot and restart your computer.
Error message: Error during installation. Interrupt <xx>
cannot be used.
Possible cause: The AVM ISDN-Controller A1 PCMCIA and an-
other hardware component (e.g. sound card) are configured
to the same interrupt.
Solution: Check which interrupts are available in your com-
puter, using the Windows NT Diagnostics program
(IRQ/Port Status). Then start the A1 PCMCIA Setup program
a1pcm_e.book Seite 51 Mittwoch, 18. Juli 2001 11:22 11
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AVM ISDN-Controller A1 PCMCIA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AVM ISDN-Controller A1 PCMCIA in the language / languages: English as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AVM ISDN-Controller A1 PCMCIA

AVM ISDN-Controller A1 PCMCIA User Manual - German - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info