814909
29
Zoom out
Zoom in
Previous page
1/36
Next page
29
Annex 1: Basic parameters & specifications of heaters
1. Basic parameters of the heater FLOW-5D, 5B
Characteristics
Models
FLOW 5B
FLOW 5D
Voltage
12V
12V
24V
Heating medium
Coolant, antifreeze coolant
Optimal liquid/coolant
volume
10 - 12 L
Coolant liquid flow rate
At 0 bar pressure:
At 0.18 bar pressure:
1200 l/h
800 l/h
Heating power
5 kW
Power consumption
42 W
Power consumption, at start
122 W
120 W
Max. work altitude (MASL)
1000 m
Fuel
Petrol fuel in accordance
with EN228
Diesel fuel in accordance with
EN590
Fuel consumption
0,7 l/h max
0,62 l/h max
Control mode
Manual, standard remote control, modem
Weight of the heater
2,4 kg
Heater dimensions
220x90x136 mm
2. Basic parameters of the heater FLOW-14D
Characteristics
Models
FLOW 14D-12
FLOW 14D-24
Voltage
12V
24V
Heating medium
Coolant, antifreeze coolant
Optimal liquid/coolant
volume
25 - 30 L
Coolant liquid flow rate
At 0 bar pressure:
At 0.18 bar pressure:
2000 l/h
1300 l/h
Heating power
14,5 kW
Power consumption
46-124 W
46-113 W
Max. work altitude (MASL)
1000 m
Fuel
Diesel fuel in accordance with EN590
Fuel consumption
0,5-1,2 l/h max
Control mode
Manual, standard remote control, modem
Weight of the heater
5,7 kg
Heater dimensions
340x160x206 mm
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autoterm Flow at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autoterm Flow in the language / languages: English as an attachment in your email.

The manual is 5.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Autoterm Flow

Autoterm Flow User Manual - German - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info