3.2.1 Installation of the coolant pump
The coolant pump must be installed in the cooling circuit upstream of the liquid
heater. The coolant pump should be installed below the level of the expansion tank,
radiator, and heater.
The direction in which the coolant flows in the pump must be the same as in the
cooling system of the vehicle/vessel.
3.2.2 Angle pipes
To assist the installation process, the angle pipes can be turned by 180° for FLOW 5
or by 90° for FLOW 14D (see Fig. 6a/b).
To turn the pipes, loosen the screw in the fixation plates. Turn the pipes to the desired
position and retighten the screw in the fixation plate.
Do not rotate the pipes while the screw is being tightened. It will damage the
gaskets and cause a leak.
Angle pipes can be changed for straight pipes in the FLOW 5 (sold separately).
The installation position of the coolant pump must not cause an airlock inside
the pump. See the permissible installation positions in Fig.5.
Fig. 6a Angle pipe fixation for FLOW 5
Fig. 6b Angle pipe fixation for FLOW 14D
Fig. 5 Position of the coolant pump
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autoterm Flow at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autoterm Flow in the language / languages: English as an attachment in your email.

The manual is 5.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Autoterm Flow

Autoterm Flow User Manual - German - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info