Editing the timer
Set the time of day for heater to start:
Set hours and confirm;
Set minutes and confirm.
Set working duration of the heater.
Duration can be set from 30min to 720min* with increasing step of 5min.
*up to 120min for liquid heaters
Set days for heater to start, where:
ED (Every Day) heater starts every day of the
week;
EW (Every Workday) – heater starts every day from
Monday to Friday;
SEL (Select specific day) heater starts only on
specified days, where:
1 – Monday
3 – Wednesday
5 – Friday
7 – Sunday
2 – Tuesday
4 – Thursday
6 – Saturday
Set the operation mode for air heaters:
Heating mode
Heat + Ventilation mode
Ventilation mode
Set the operation mode for liquid heaters:
Pre-heating mode
When all the parameters are set message “Saved” is shown on the display and
the timer is enabled automatically. Enabled timers can be seen on the bottom
part of the main screen. LED indicators will blink light green once every 5sec
when timer is enabled.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autoterm Comfort Boiler Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autoterm Comfort Boiler Control in the language / languages: English as an attachment in your email.

The manual is 1.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info