Oscilloscope Operations Screen Layout and Operations
120
15.4.2 Functional Buttons
This group of buttons is used for configurations of channel activation,
measurement scale and trigger settings, the operations of which are described
below:
Channel Control Buttons A/B/C/D - tapping each button allows you to
activate or deactivate the corresponding channel; long pressing the
button opens a window, which allows you to select and configure
appropriate probes for specific tests.
The Channel Control Buttons are displayed in different colors as follows:
A. Red
B. Green
C. Blue
D. Pink
AC/DC Coupling and Voltage Scale Buttons tapping this button
opens a dropdown menu, on which you can select AC or DC
measurements and adjust voltage measurement scales.
The Auto voltage scale option enables the scope to adjust the voltage
scale automatically to capture the signal.
AutoScale tapping this button enables automatic set-up of the voltage
scale and time base for the signals received.
Start/Stop tapping this button turns on/off the scope.
Single tapping this button activates the Single trigger mode when the
trigger is on. The Single trigger mode configures the trigger to occur
once when the scope captures the first signal waveform by the preset
trigger point.
15.4.3 Measurement Grid
The 2 control features - Voltage per division and Time per division enable
the users to adjust the scope settings to suit the particular test measurement.
127


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autel MaxiSys at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autel MaxiSys in the language / languages: English as an attachment in your email.

The manual is 5,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Autel MaxiSys

Autel MaxiSys User Manual - German - 149 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info