27
12 Operation
12.1 Before heating up
The stove can only function properly if there is sufficient combustion air coming to the room of installa-
tion (the appliance), specially if several firing installations are being operated at the same time. Ensure
sufficient air supply before heating up. Open the combustion air flap on the stove and keep it open for
the entire combustion period.
Devices for the supply of combustion air must not be modified.
12.2 Making fire correctly
To ensure the stove operates correctly and safely, it is important that the chimney generates the re-
quired draft. This must be checked in particular for each initial commissioning (e.g. after summertime)
and in the transitional periods (e.g. when the wind is strong). If there is insufficient required draft, then
paper or softwood chips can first be burnt in order to bring stove and chimney flue to temperature.
The air inlet of the stove must not be closed.
1) Clean grate.
2) If necessary empty ash box/ash pan (beware of em-
bers).
3) Completely open the secondary air controller.
ðPosition “UP”
1
2
3
Fig.7: Before kindling
4) Lay 2-3 pieces of log (1) (beech, oak, birch) across the
bottom of the firebox.
5) Finely split softwood above it (2).
6) Place a firelighter (3) in the middle and light it.
ðNever use petrol, spirit or similar for ignition!
1 Log
2 Softwood
3 Firelighter
7) Close the door.
ðIt is best to allow the first layer of wood to combust
without altering the air damper setting.
ðIf only the bed of embers is left (no more flames),
you can place another layer of log.
8) When stoking up, proceed as for heating up:
ðOpen combustion air supply.
ðCarefully open stove door.
ðPut wood on.
ðClose door.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Wien at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Wien in the language / languages: English as an attachment in your email.

The manual is 8.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Austroflamm Wien

Austroflamm Wien User Manual - German - 46 pages

Austroflamm Wien User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info