810578
59
Zoom out
Zoom in
Previous page
1/74
Next page
Operating manual Ruby EN 16 | Electrical connection diagram
59
16 Electrical connection diagram
16.1 Electrical connection
NOTICE
Repairs to your pellet stove must only be carried out by authorised Austroflamm engineers.
Fig.ī˜…83: Fuse holder with T2.5A glass tube
fuses
Your pellet stove is designed for connection to a 230 Vī™‹/ī™‹50
Hz mains. The connection cable is included.
The mains socket connection is located on the rear of the
appliance and is protected with a T2.5 A glass tube fuse.
The power consumption of your pellet stove is visible on
the nameplate.
16.2 Model with permanently running screw motor
1. Phase converter
2. RPM / HAL-IC
Earth - induced-draft fan
3. Earth - DC control side
4. Room temperature sensor
5. Firebox temperature sensor
6. Differential pressure measurement P1, P2
7. Ceramic ignition
8. Induced-draught fan
9. Air distribution module (optional)
10. Control - permanently
running screw motor
11. Safety temperature limiter
12. Hopper lid switch
13. Grate motor, power release for
auger motor
14. Grate motor
(OPT) External thermostat
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Ruby at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Ruby in the language / languages: English as an attachment in your email.

The manual is 26.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Austroflamm Ruby

Austroflamm Ruby User Manual - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info