10 english
9.2 Technical Data
Modell
45x K
45x51
KII
55x K
65x K
75x K
75x39
KII
38x38x57
K
55x55x
K
63x40x42
K
Testing according to DIN EN
13229
CE - Marking
Nominal output
kW
6
6
7
8
10
10
5
7
8
Max. heating capacity
kW
8
8
9
11
15
15
6
9
11
Max. firewood length
cm
33
33
33
33
33
33
33
33
33
Permissible quantity of fuel
kg
1,7
1,7
1,9
2,35
3,2
3,2
1,34
1,9
2,35
Fuel throughput
kg/h
1,7
1,7
2
2,3
2,85
2,85
1,6
2
2,3
Cross section convection outlet
cm²
700
700
700
700
700
700
500
700
700
Cross section convection inlet
cm²
700
700
700
700
700
700
500
700
700
Power output via window
%
14/17/17
23
14/17/20
17/20/20
17/23
29
37
32/35
37
Emission limits
CO based on 13% O2
mg/m³
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
≤1250
Dust based on 13% O2
mg/m³
≤40
≤40
≤40
≤40
≤40
≤40
≤40
≤40
≤40
CnHm
mg/MJ
≤50
≤50
≤50
≤50
≤50
≤50
≤50
≤50
≤50
NOx based on 13% O2
mg/m³
≤150
≤150
≤150
≤150
≤150
≤150
≤150
≤150
≤150
Efficiency
min.%
≥80
≥80
≥80
≥80
≥80
≥80
≥80
78,9
≥80
Exhaust gas temperature***)
°C
354/371/387
292
275/313/351
283/298/317
313/300
286
273
330
230
Exhaust gas mass flow
g/s
5,1/5,2/5,2
5,5
5,9/6,0/6,2
7,3/7,7/6,8
8,1/7,7
7,3
5,0
7,5
7,65
Minimum discharge pressure
Pa
12
12
12
12
12
12
12
14
12
Distances from the fireplace insert
to the firebox wall
cm
6
Information on fire and heat protection (data in mm Promasil 950 KS)
Insulation thicknesses
to the installation floor
mm
60
20
60
60
60
20
-
-
-
at the side/rear
mm
90
130/-
90
90
120
130/-
90
60
100/120
to the ceiling
mm
according to the national or local standards (e.g.: TR OL, FeuVo)
Radiation area side viewing window
cm
--
-
--
--
--
--
85
80
110
Radiation area front viewing window
cm
80
110
80
80
80
80
85
80
110
Combustion air
Combustion air connecting
hose (K/S)
Ø mm
125
125
125
125
125
125
125
125/150
150
Combustion air requirement
(A1)
m³/h
12
17,8
14
17,5
19,5
16,71
12
22
44
Application with a special construction
Hypocausts**)
suitable in compliance with technical regulations
*) under examination
**) The Austroflamm appliances marked with "suitable in line with technical regulations" are suitable for
operation in closed systems (hypocaust).
***) on the connecting piece of the appliance at nominal heat output
10 Warranty and Guarantee
Installation and delivery of the device by a specialist company are prerequisites for the manufacturer's
warranty, as is compliance with the applicable building regulations. We would also like to point out that the
fireplace must not be modified. Any structural changes or use other than for the intended purpose will render
any warranty claim null and void!
We guarantee flawless operation of the body of your Austroflamm fireplace insert for 6 years. All other steel
and cast iron components are guaranteed for 2 years from the date of first sale. Steel and cast iron parts that
show material and/or processing defects during the warranty period will be replaced with new parts.
We do not grant any warranty for wear and tear parts (e.g. ceramic, seals, floor grating), surface coatings,
paintwork and glass. Our warranty service includes new parts free of charge. Labour and travel times are not
included.
An unjustified warranty claim will be charged to the provider.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Miu at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Miu in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info