Irony XS 4 english
1. TECHNICAL DATA
As a stove of construction type 1, it is possible to
connect it to the flue pipe of an existing other stove or
another hearth for solid fuels, as long as the chimney
does complies with DIN 4705, Part 3.
.
TECHNICAL DATA
Hei
ht 1309 mm
Width 675 mm
De
p
th 482 mm
Wei
g
ht 230 k
g
Wei
g
ht with ceramic shell 268 k
g
Flue
p
i
p
e outlet diameter 150 mm
Nominal thermal out
p
ut
(
EN 13240
)
8 kW
Maximum thermal capacity 11 kW
Smallest heating capacity 4 kW
Room heating capacity (depending
on building insulation)
73 – 186 m³
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
accordance with DIN 4705, Part 2
Fluegas mass flow closed 8 g/s
Fluegas temperature closed 340 °C
Minimum feed pressure
Nominal thermal output
closed 12 Pa
at 0.8 times
n. ther. outp.
10 Pa
2. IMPORTANT INFORMATION
The installation and operation information given here
is of general nature.
National and European
standards, local and building regulations as well as
fire prevention laws must be observed during the
operation of the stove.
General safety instructions for
the operation of your stove
Thoroughly read the entire manual before
starting up your stove and observe the caution
notices.
Your heating unit may not be moved without
approved means of transport with sufficient load-
bearing capacity.
Your heating unit is not suitable to be used as a
stand or as a ladder.
The burning of fuel releases thermal energy that
leads to a substantial heating up of the surface of the
heating unit, the doors, the operating handles
mounted on the door, door glass, flue pipe and in
some cases the front wall of the heating unit. Do not
touch any of these surfaces without respective
protective clothing or without the help of accessories
such as heat-resistant gloves or a cold hand.
Make your children aware of this particular
danger and keep them at a distance from the heating
unit whenever it is in operation.
Only burn approved fuels and materials listed in
the chapter “Clean Burning”.
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like
into the firebox as well as the storage of such
materials in the immediate vicinity of your heating unit
is strictly forbidden due the danger of explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
Placing non-heat-resistant objects on the
heating unit or in the vicinity of the heating unit is
forbidden.
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe
distance from the stove because of the danger of fire.
The woodstove Irony XS is not suitable for long
term heating.
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in
the same or an adjacent room to the one in which
your heating unit is located
.
Setting up your stove
Required safety distances (Minimum
distances – see name plate - in Fig. 2)
1. To nonflammable objects:
a > 400 mm b > 200 mm
2. To flammable objects and to supporting walls of
reinforced-concrete construction with convection
shell:
a > 800 mm b > 200 mm
(a – toward the front in the radiated area)
(b – to the side and to the back)
Make sure that the room in which the stove is set up
has at least one door or window into the outside or is
directly adjacent to such a room. Other fireplaces and
extractor hoods must not be operated in the same
room as the stove
.
Subject to technical and optical modifications. Formatting and printing errors excepted.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm IRONY XS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm IRONY XS in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info