5 | Technical data EN Operating manual Fireplace inserts slied flat + II
48
5.2 General specifications
Model 65x S 75x S 75x39
SII
75x51
SII
80x64 S
80x64
SII
97x45 S 97x74 S 120x45
S
EN test EN 13229 CE mark
Nominal heat efficiency in [kW] 8 10 10 12 10 11 12 13
Maximum heat output [kW] 11 14 14 16 15 16 17 17
Max. length of logs 33 33 33 33 33 33 33 33
permissible fuel filling quantity [Kg] 2.35 3.2 3.2 3.4 3.2 3.4 3.4 3.5
Fuel throughput, maximum [kg/h] 2.3 2.85 2.85 3.5 2.13 2.56 2.56 3.97
Cross-section, convection outlet [cm²] 700 700 700 1820 1000 1200/
1000
1200/
1000
2940
Cross-section, convection inlet [cm²] 700 700 700 1170 1000 1000 1000 2320
Power output via pane [%] 17/
20/20
17/
23
29 34 29/
50
23/
28
23/
28
32
Emissions values
65x S 75x S 75x39
SII
75x51
SII
80x64 S
80x64
SII
97x45 S 97x74 S 120x45
S
CO [mg/Nm³] ≤1250 ≤1250 ≤1250 ≤1250 ≤1250 ≤1250 ≤1250 ≤1250
Dust based on 13% O2 ≤40 ≤40 ≤40 ≤40 ≤40 ≤40 ≤40 ≤40
OGC [mg/MJ] ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50
NOx based on 13% O2[mg/m³] ≤150 ≤150 ≤150 ≤150 ≤150 ≤150 ≤150 ≤150
Efficiency [%] ≥80 ≥80 ≥80 ≥80 ≥80 ≥80 ≥80 ≥80
Flue gas temperature [°C]
***)
283 /
298 /
317
313/300 286 252 312/291 274/288 274/288 254
Flue gas mass flow [g/s] 7.3 /
7.7 / 6.8
8.1/7.7 7.3 13.07 8.28/8.4
3
9.9 9.9 14.88
Minimum feed pressure at nominal
heat output [Pa]
12 12 12 13 12 12 12 13
Distances from fireplace insert
65x S 75x S 75x39
SII
75x51
SII
80x64 S
80x64
SII
97x45 S 97x74 S 120x45
S
Distances from fireplace insert to
heating chamber wall [cm]
6
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II in the language / languages: English as an attachment in your email.

The manual is 14.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II

Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II User Manual - German - 124 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info