694346
85
Zoom out
Zoom in
Previous page
1/88
Next page
english 82
10.2. Percy
Nominal thermal output (NWL)
8.6 kW
Partial-load thermal output
2.4 kW
Space heating capacity
50 - 240 m³
Degree of effectivity
90.20%
CO content at NWL
36.7 mg/Nm³
CO content at partial load
338 mg/Nm³
Flue gas temperature at NWL
208 °C
Flue gas temperature at TL (partial load)
90°C
Flue gas mass flow rate at NWL
6.13 g/s
Flue gas mass flow rate at TL
3.17g/s
Minimum delivery pressure at NWL 12 Pa
Minimum delivery pressure at TL 9 Pa
Capacity of filling tank
25 kg / 39 l
Min./max pellet consumption
0.6 - 2.1 kg/h
Min./max autonomy
Approx. 12 - 42 h
Air connector Ø
80 mm
Flue connector Ø
80 mm
Current at switch on
300 W
Current in operation
25 W
Voltage/current frequency
230 V / 50 Hz
Dimensions
H x W x
D
1120 x 526 x 517 mm
Weight
181 kg
Minimum distance
At side 100 mm
At back 100 mm
At front 800 mm
Temperature limits 0 - 40°C
Relative humidity Non-condensing
83 english
10.3. Polly 2.0 / Polly light
Nominal thermal output (NWL) 7.8 / 9 kW
Partial-load thermal output 2.4 / 2.7 kW
Space heating capacity 50 - 240 m³
Degree of effectivity 90.7 / 90 %
CO content at NWL 47 / 29 mg/Nm³
CO content at partial load 173 / 251.8 mg/Nm³
Flue gas temperature at NWL 206 / 204 °C
Flue gas temperature at TL (partial load) 115 / 105 °C
Flue gas mass flow rate at NWL 4.9 / 5.98 g/s
Flue gas mass flow rate at TL 3.0 / 4.16 g/s
Minimum delivery pressure at NWL 12 Pa
Minimum delivery pressure at TL 9 Pa
Capacity of filling tank 25 kg / 39 l
Min./max pellet consumption 0.6 - 1.9 kg/h / 0.7 - 2.2 kg/h
Min./max autonomy Approx. 13 - 42 h / 11 - 39 h
Air connector Ø 80 mm
Flue connector Ø 80 mm
Current at switch on 300 W
Current in operation 29.9 W
Voltage/current frequency 230 V / 50 Hz
Dimensions H x W x D 1100 x 520 x 498 mm
Weight 158 kg
Minimum distance At side (Niche) 100 mm
At side (Wall) 200 mm
At back 100 mm
At front 800 mm
Temperature limits 0 - 40°C
Relative humidity Non-condensing
englisch
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Ben at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Ben in the language / languages: English, German, French as an attachment in your email.

The manual is 5,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Austroflamm Ben

Austroflamm Ben User Manual - Dutch - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info