EKH-S, EWH Id. Nr.: 248735-6
INSPECTION, MAINTENANCE, SERVICE
a) During heating, the expansion water must drip visibly from the drain of the safety valve. The expansion water
quantity is approx. 3.5% of the tank’s rated volume when fully heated (approx. 80 °C).
The function of the safety valve must be checked regularly. The water must ow freely from the safety valve unit
into the drain funnel when the safety valve test knob is lifted or turned to the Test position.
Caution: the cold water supply and parts of the storage tank connector ttings may become hot thereby.
If the water heater is not heated up or hot water is withdrawn, no water must drip from the safety valve. If this is
the case, then either the water line pressure is too high (install pressure reducing valve over 5.5 bar) or the safety
valve defect. Please call a plumbing expert immediately!
b) The boiler scale as well as the furring forming in the internal boiler of the tank must be removed by an expert
after one to two years of operation in the case of heavily calciferous water.
Cleaning is performed through the ange opening. De-install heating ange, clean tank; a new seal must be
used in any case when the heating ange is mounted. The internal tank of the water heater with special ena-
melling must not get in contact with boiler scale solvents – do not use an anti-liming pump. Remove lime
deposits with wood and aspirate or wipe out using a cloth.
Then rinse the device thoroughly (in accordance with ÖNORM H5195-1) and observe the heating process in
the same way as during rst commissioning.
c) In order to ensure a corrosion protection and be entitled to any claims for warranty, as provided on the side
of the manufacturer, the installed magnesium anode requires checking by an expert at intervals of 2 years of
operation (EKH-S 5 years). The guard circuit shunt resistor below the heating unit fastening screw must not be
damaged or removed during maintenance works.
d) Do not use any abrasive cleaning agents and paint thinners (such as nitro, trichlor etc.) to clean the device.
The best cleaning method is to use a damp cloth added with a few drops of a liquid household cleaner. In hos-
pitals and other public buildings, the prevailing regulations for cleaning and disinfection must be observed.
During maintenance works, it is advisable to open the cleaning and service ange in order to check the tank for
any possible washing-in of foreign objects and contaminations, and to remove these if necessary.
MALFUNCTIONS
If the tank water is not heated, please check whether the line circuit breaker (automatic safety cutout) or the safety
fuse in the distribution box have reacted, and check the setting of the temperature control.
In all other cases, do not attempt to rectify the fault yourself. Please contact either a licensed plumber or our custo-
mer service. In many cases it only needs a little manipulation by an expert and the tank is in order again. In case
of contact, please quote your model designation and manufacturing number, which you can nd on the rating
plate of your electric tank.
RECYCLING AND DISPOSAL
Always dispose of materials according to environmental, recycling and waste management standards.
All appliances, wearing parts, defective components and environmentally hazardous liquids and oils must be
disposed of or recycled according to applicable waste disposal regulations without harming the environment.
They must not be disposed of as household waste.
Dispose of packaging made of cardboard, recyclable plastics and synthetic ller materials in an en-vironmen-
tally responsible manner through appropriate recycling systems or at a recycling centre.
Please observe the applicable national and local regulations.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austria Email EWH serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austria Email EWH serie in the language / languages: English, German as an attachment in your email.

The manual is 2.08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info