OPERATING CONDITIONS
The tanks must be used exclusively in accordance with the conditions specied on the rating plate. The
maximum inlet pressure corresponds with the nominal pressure stated on the rating plate. Aside from
the legally approved national regulations and standards, the connecting requirements of the local power
company and waterworks, as well as the Mounting and Operating Instructions must be complied with.
The room in which the device is operated must be free of frost.
The device must be mounted at a location that may reasonably be expected, i.e. it must be possible to
access and replace the device without diculties for the purpose of necessary maintenance, repairs and
possible replacement. The hot water tank must only be connected with permanent piping. In the case of
heavily calciferous water, we recommend the upstream integration of a customary anti-liming device or a
maximum operating temperature of approx. 65 °C (position ••).
An appropriate quality (according to drinking water ordinance) of drinking water is required for proper ope-
ration. To avoid possible ingresses of particles, we recommend the upstream integration of a water lter.
Should a device, at the point of delivery, clearly display a malfunction, damage or other defect, this must
not be tted, installed or used in the system. Subsequent complaints regarding devices with an obvious
defect which have been connected and installed are expressly excluded under the warranty and guaran-
tee.
MOUNTING AND SAFETY INFORMATION
a) Important mounting information! Do not bend hang-up hook safety element due to
possible fracture. Risk of injury by falling device in the case of non-observance!
b) A wall rail for hanging up the upper fastening hook is enclosed with every device,
which is mounted to the wall using two screws and takes over the supporting functi-
on.
Two additional screwed connections must be provided on the wall (in accordance
with the dimensioned drawing with the device dimensions) for the lower wall plate of
the device; this has only a supporting function against the wall as well as against late-
ral shifting. The lower wall bracket has no supporting function and may therefore not
be subject to any excessive stress. Lifting and/or supporting the electrical storage he-
ater on the lower wall bracket is prohibited, as this strain can lead to the wall bracket
tearing o! Hot water heaters of a suspended type must not be mounted horizontally.
c) The fastening hooks and with that the hang-up dimension A can be adjusted at inter-
vals of 50 mm by repositioning the rear tank wall screws into other holes of the hook
(only for 50 – 150 litres). The attachment hook is always to be secured to the rear wall
of the tank with at least two screws.
Caution: Only xing hooks provided by the manufacturer may be used!
If the assembly height is changed, this is to be tightened to the mounting screws with a torque of 40 - 50 Nm.
d) The dimensioned device drawings and any information labels that may be enclosed must be observed during
mounting.
e) Caution: the weight of the water heater including the weight of the water lling (the rated capacity) must be
taken into account for load-related and strength-related design of the device mounting surface or selection of
the mounting location.
Special suspensions: see thin-wall and/or ceiling suspension.
f) If a water heater is provided with enclosures (covering), installed in narrow, small rooms or in suspended cei-
lings and the like, it is absolutely important to check that the connecting side of the device (water connections,
electric connecting area or heating unit) remains freely accessible and no accumulation of heat results. A free
space of 500 mm must be available for de-installation of the heating ange. A space of at least 50 mm must be
kept free above the device for hanging it up on the wall rail.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austria Email EHT serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austria Email EHT serie in the language / languages: English, German, Italian as an attachment in your email.

The manual is 2.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info