Operation
0HR = present barometric pressure
1HR = barometric pressure an hour earlier
2HR = barometric pressure two hours
earlier, etc.
Press and hold down the “+“ / °C / °F button
28
for about 3 seconds to switch between
displaying the barometric pressure units in
inHg or mb / hPa.
Setting the channel
To do this open the battery compartment on
the back of the outdoor sensor and take it off.
Set the channel by means of the Channel
selection switch
39
.
Press the channel button
26
for approx. 3
seconds until a signal is sounded. The wea-
ther station has now received one signal.
Press the TX button
42
to transmit the measured
temperature to the weather station manually.
Then close the battery compartment
40
.
Displaying the outdoor
temperature
Press the Channel button
26
to display the
outdoor temperature of each outdoor sensor.
Press the Channel button
26
1 x to display
channel 1.
Press the Channel button
26
2 x to display
channel 2.
Press the Channel button
26
3 x to display
channel 3.
Press the Channel button
26
4 x to display
all the channels one after the other in a loop.
Only the outdoor sensors which can be
addressed are displayed.
Press and hold down the Channel button
26
to remove unused channels. If a further out-
door sensor and channel are added later,
the weather station will receive the signal
automatically. Alternatively, you can also
transmit the initial signal from the outdoor
sensor manually by pressing the TX button
42
.
Displaying the temperature
trend (outdoor)
After successfully connecting with the outdoor
sensor, the weather station can display the
Temperature trend
21
.
You may see the following displays:
= The outdoor temperature is rising.
= The outdoor temperature is remaining
constant.
= The outdoor temperature is falling.
Displaying the indoor
temperature
The current Indoor temperature
3
is shown in
the LC display.
Displaying temperatures
in °C / °F
Note: °C is the legally required temperature unit.
Note: The weather station is supplied in the
default setting of °Celsius.
Press the “+“ / °C / °F button
28
to switch
between the Celsius and Fahrenheit tempera-
ture scales.
Displaying the air humidity
(indoor)
The current air humidity
5
is shown in the LC
display. The Comfort indicator
4
displays the
air humidity in three categories.
The following categories are available:
“Dry” = Air humidity
5
< 45 %
“Comfort” = Air humidity
5
45–75 %,
indoor temperature
3
24 °C–27.9 °C
Wet” = Air humidity
5
> 75 %
Displaying the maximum /
minimum temperature /
humidity
The minimum / maximum temperature / humidity is
measured for the first time after the batteries have
been inserted and stored in the weather station.
Press the
“–“ / MAX / MIN
button
29
briefly.
The maximum indoor
3
and outdoor tem-
perature
24
measured and the maximum
humidity
5
measured are shown.
Press the
“–“ / MAX / MIN
button
29
again
briefly. The minimum indoor
3
and outdoor
temperature
24
measured and the minimum
humidity
5
measured are shown.
Press the
“–“ / MAX / MIN
button
29
again
briefly to return to the current values.
Note: If no button is pressed within 5 seconds,
the displays automatically return to the
standard display.
Hold the
“–“ / MAX / MIN
button
29
down
for approx. 3 seconds in order to delete the
stored maximum and minimum values when
you hear a beep sound. The values measured
from the time of deletion of the old values
until the next time the memory is called up
can be called up again.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Auriol Z31092 - IAN 68756 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Auriol Z31092 - IAN 68756 in the language / languages: English, Danish, Swedish, Finnish as an attachment in your email.

The manual is 1,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Auriol Z31092 - IAN 68756

Auriol Z31092 - IAN 68756 User Manual - German, Dutch, French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info