6
h) DIP switch
DIP switches are ON” when down and OFF” when up. The default setting is with all switches set OFF (up).
The table below describes their eect.
**In a system with only a single MULTIzone unit, if DIP switch 5 is set ON then any microphone signal will duck the music signal in
whichever zone(s) the microphone level is set above zero – but the microphone signal will not be heard.
i) Remote Zone Controller inputs
Four RJ-45 sockets for connection to remote Zone Control wall plates. Connect via an 8-way CAT-5 cable terminated with RJ-45
plugs at each end for each Zone. The Zone Control wall plate takes over control of Zone input select and volume control – disabling
the front panel controls for that zone. See Appendix 2 for further details.
j) RS-232 control input
9-pin male “D-type” connector. See Appendix 4 for further details and the RS-232 control protocol.
j
i h
SW Function
DIP switch UP
DIP switch DOWN
Notes
OFF
ON
1 RS-232 Address LSB 0 1
Use these switches to set the “unit number”
for RS-232 addressing. See Appendix 4 for
details.
Set all three switches to “0” (UP) to lock the
unit into Manual mode – disabling all RS-232
control.
2 RS-232 Address 0 2
3 RS-232 Address MSB 0 4
4
RS-232 source –
when unit is SLAVE
Unit is controlled from
local RS-232 socket
RS-232 control from
LOOP input
When unit is master, RS-232 signal is sent to
LOOP out – so DIP switch has no effect.
5
MIC source –
when unit is SLAVE
Local microphone “ducks”
unit’s Zone outputs
Master (LOOP) microphone
“ducks” unit’s Zone outputs
When unit is master, ducking signal is sent to
6
Phantom Power
off
on
7
Zone 1 Audica EQ
off
AEQ
Audica speaker EQ
is designed to optimise
performance from Audica Pro loudspeakers.
If Audica Speaker EQ is to be used in a system
with a subwoofer, please refer to Appendix 5.
8
Zone 2 Audica EQ off AEQ
9
Zone 3 Audica EQ
off
AEQ
10
Zone 4 Audica EQ
off
AEQ
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Audica Multizone at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Audica Multizone in the language / languages: English as an attachment in your email.

The manual is 1,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info