ACCUMULATION TANKS
EN
DESCRIPTION
ATTACK S– is based on the ATTACK AK type. Disk and stratied pipe in-
stalled in the exchanger enable creation of water layers according to the
temperature. This construction ensures dierent temperature layers at
the inlets and outlets.
ATTACK SS – is based on the ATTACK AS and the ATTACK Stypes. It is
accessorized with an extra exchanger for connection to the solar circuit.
ATTACK S: 10× socket G1 ½", 5× socket G½"
ATTACK SS: 10× socket G1 ½", 5× socket G½", 2× socket G1" – solar circuit
KEY FOR THE ACCUMULATION TANKS
1 – Flow connection – boiler . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . 1 ½"
3 – Electrical heating coil (EL) . . . . . . . . . . 1 ½"
4 – Freely disposable . . . . . . . . . . . . . . . . 1 ½"
5 – Return connection – heating circuit . . . . 1 ½"
6 – Flow connection – heating circuit (radiators) 1 ½"
7 – Flow connection – heating circuit (oor) . 1 ½"
8 – Return connection, gas, oil or pellet boiler 1 ½"
9 – Return connection – wood boiler . . . . . 1 ½"
10 – Sensor of solar system or heating . . . . . . ½"
AS – Flow connection of solar system . . . . . . . 1"
RS – Return connection of solar system . . . . . . 1"
SF – Upper solar sensor . . . . . . . . . . . . . . . . ½"
SU – Bottom solar sensor . . . . . . . . . . . . . . . ½"
D1 – Diameter without insulation
D2 – Diameter with insulation
TECHNICAL PARAMETERS
Tank Solar
exchanger Tank
Typ
Energy eciency class
Position 1–6
Position 27
Position 3
L – max. length of the electric
heating body
Position 4–8
Position 5–9
Position SU
Position SF
Position RS
Position AS
D1 – Diameter without
insulation
D2 – Diameter with insulation
of 100 mm
Height
Height with insulation of 100 mm
R – Slope dimension without
insulation
Max. operating temperature (°C)
Static loss (W)
Max. operating pressure (bar)
Area of exchanger (m²)
Volume of exchanger (l)
Max. operating pressure (bar)
Volume (l)
Weight (kg)
S500K C 1405 1013 871 700 621 230 461 1209 - - 650 850 1680 1730 1698 95 - 3 - - - 488 102
S800K - 1545 1135 946 840 725 315 491 1340 - - 790 990 1842 1892 1898 95 105 3 - - - 713 132
S1000K - 1735 1255 1036 840 775 295 577 1495 - - 790 990 2031 2082 2081 95 121 3 - - - 891 141
S1250K - 1655 1175 988 1000 695 285 565 1415 - - 950 1150 1975 2025 2064 95 142 3 - - - 1239 186
S1500K - 1755 1345 1072 1050 820 375 653 1545 - - 1000 1200 2100 2150 2160 95 161 3 - - - 1420 232
S2000K - 1955 1408 1314 1150 862 315 685 1682 - - 1100 1300 2309 2356 2390 95 188 3 - - - 1960 330
SS500K C 1405 1013 871 700 621 230 461 1209 230 710 650 850 1680 1730 1698 95 - 3 1,8 11,9 10 488 139
SS800K - 1545 1135 946 840 725 315 491 1340 315 725 790 990 1842 1892 1898 95 105 32,4 15,9 10 713 173
SS1000K - 1735 1255 1036 840 775 295 577 1495 295 860 790 990 2031 2082 2081 95 121 3 3 19,8 10 891 197
SS1250K - 1655 1175 988 1000 695 285 565 1415 285 850 950 1150 1975 2025 2064 95 142 3 3 19,8 10 1239 243
SS1500K - 1755 1345 1072 1050 820 375 653 1545 375 895 1000 1200 2100 2150 2160 95 161 33,6 23,7 10 1420 296
SS2000K - 1955 1408 1314 1150 862 315 685 1682 315 665 1100 1300 2309 2356 2390 95 188 34,2 27,7 10 1960 330
138


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK TUV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK TUV in the language / languages: English, German, French as an attachment in your email.

The manual is 9.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info