810506
85
Zoom out
Zoom in
Previous page
1/120
Next page
84
EN
Pic. 58 Advanced parameters, page 5
Regulator worktime (SEC) – PID control model conversion time of secondary – airflap
Regulator P – part (SEC) – proportional part of the PID control model of secondary – airflap
Regulator I – part (SEC) – integral part of the PID control model of secondary – airflap
Regulator D – part (SEC) – differential part of the PID control model of secondary – airflap
Exhaust temperature Stop – if the flue gas temperature falls below this value for 15 min. or
the oxygen content of the flue gas will be greater than 14% for 15 minutes, the boiler will shut
down and the display will indicate that there is a lack of fuel in the boiler. By setting this value to
a higher value, you can influence the remaining amount of carbons in the boiler loading cham-
ber for easier subsequent heating. The higher the value, the greater the amount of hot coals that
remain
Exhaust temperature Stop – is the value below which when the flue gas temperature drops,
the boiler will report a lack of fuel
Set night from (hour)if the heating circuit is connected we determine the hour of night start
when the heating circuit can reduce the temperature
Set night to (hour)if the heating circuit control is connected we determine the hour of night
termination
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK SLX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK SLX in the language / languages: English as an attachment in your email.

The manual is 12.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK SLX

ATTACK SLX Additional guide - English - 21 pages

ATTACK SLX User Manual - German - 112 pages

ATTACK SLX Additional guide - German - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info