Stromlaufplan des Reglers: λ – Modul der Lambda-Sonde, B – Modul für die Heizkreise 3 und 4, BH – oberer Temperatursensor des Pufferspeichers vom Typ CT4, BL – unterer Temperatursensor des
Pufferspeichers vom Typ CT4, RPM – Drehzahlsensor des Lüfters, H – Spannungsausgang 12V zur Steuerung: Ersatzkessel R, Alarm AL, Zirkulation der Pumpe für warmes Brauchwasser Relais 12VDC, DZT -
Öffnungssensor der Kesseltür / thermische Anlaufsicherung des Brenners , RP–Raumthermostat ecoSTER TOUCH/ecoSTER200, BP – Bedienpaneel, M1–Temperatursensor des Mischers 1 vom Typ CT4, M2/RS -
Temperatursensor des Mischers 2 vom Typ CT4, WS - Außensensor vom Typ CT6-P, HW - Temperatursensor für warmes Brauchwasser vom Typ CT4, T2 – Standard-Raumthermostat, BT - Kessel-Tempatursensor
vom Typ CT4, FT – Abgastemperatur-Sensor vom Typ CT2S, L N PE - Stromspeisung 230V~, STB – Eingang für den Notfallthermostaten für die Temperatur, FH –Pellet-Austragung, CF - der Lüfter des Brenners,
eco DRIVE – Elektronik der Brennerreinigung, IG – Zündung, BP – Kesselpumpe, DH – Pumpe für warmes Brauchwasser, SM – Motor für den Mix 1 und 2, PM – Pumpe des Mix 1 und Mix 2, BC - Reinigung des
Wärmetauschers und des Aschebehälters, CPU – Steuerelektronik, OS - Lichtschranke.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for ATTACK Pellet 30 Automatic Plus at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of ATTACK Pellet 30 Automatic Plus in the language / languages: German as an attachment in your email.
The manual is 0.78 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
Others manual(s) of ATTACK Pellet 30 Automatic Plus
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.