Pump protection function
The controller performs the function of protecting the DHW pump, DHW pump and mixers
against blockage. It depends on their periodic activation (every 167 hours for a few
seconds). This protects the pumps from immobilization due to limescale build-up.
Therefore, when the boiler is not in use, the power supply to the controller should be
connected. The function is also performed when the controller is OFF using the keypad
(the controller is in the "boiler off" state).
Pellet tank feeder
After connecting add-on module B, the controller can cooperate with the low fuel level
sensor in the tank (fuel supply from the additional tank). After activating the sensor, the
controller activates the auxiliary feeder to refill the basic fuel tank.
Mains fuse replacement
The mains fuse is located inside the controller housing. The fuse may only be replaced by a
qualified person after disconnection from the mains. Use time-lag fuses, 5 x 20 mm
porcelain, with a rated current of 6.3 A.
Control panel replacement
It is not recommended to replace the control panel itself because the program in the panel
must be compatible with the program in the control module.
Lambda probe
The efficiency of the burner can be increased by connecting another oxygen sensor
module which should be connected according to the wiring diagram. Probe operation
must be enabled in the menu:
Service settings ĺ Boiler settings ĺ Lambda probe
If the Lambda Sensor Operation parameter is set to ON, the controller will operate using
data from the oxygen sensor. The amount of air supplied to the furnace is automatically
adjusted to obtain the desired oxygen content in the flue gas. If this parameter is set to
OFF, the values from the Lambda probe will not affect the operation of the controller. The
required oxygen values for the individual burner outputs are entered in the menu:
Service settings ĺ Boiler settings ĺ Power modulation
It may be necessary to calibrate the oxygen sensor readings regularly. To calibrate
the probe, the boiler must first be switched off. For the calibration to take place
correctly, the fire in the boiler must be completely extinguished. The following
parameter is used to start the calibration:
Boiler settings ĺ Lambda probe calibration
The calibration process takes approximately 8 minutes.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Pellet 30 Automatic Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Pellet 30 Automatic Plus in the language / languages: English as an attachment in your email.

The manual is 0.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK Pellet 30 Automatic Plus

ATTACK Pellet 30 Automatic Plus User Manual - German - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info