810507
52
Zoom out
Zoom in
Previous page
1/60
Next page
50
14.1.1
Feeder cycle time
sec 10
14.1.2
Maximum boiler output
kW 12
14.1.3
Average boiler output
kW 6
14.1.4
Minimum boiler output
kW 3
14.1.5
100% fan power
ot/min 2400
14.1.6
50% fan power
ot/min 1800
14.1.7
30% fan power
ot/min 1100
14.1.8
50% H2 hysteresis
°C 5
14.1.9
30% hysteresis H1
°C 3
14.1.10
Boiler hysteresis
°C 10
14.1.11
Control mode
FuzzyLogic
14.1.12
Room thermostat
0
14.2.1
Fuel dose
g 130
14.2.2
Ignition test time
sec 60
14.2.3
Warm-up time
sec 60
14.2.4
Ignition time
min 9
14.2.5
Burning time
min 2
14.2.6
Burner fan power at ignition
ot/min 1580
14.2.7
Flame detection
% 10
14.2.8
Ignition of the burner fan
ot/min 1100
14.2.9
Burner fan power after ignition
ot/min 1450
14.3.1
Burner fan power during cleaning
ot/min 2650
14.3.2
Exchanger cleaning - work
sec 10
14.3.3
Cleaning time before ignition
sec 15
14.3.4
Cleaning the burner at night
NO
14.3.5
Burner cleaning cycles
3
14.4.1
Burner fan power during burnout
ot/min 1800
14.4.2
Maximum burn-up time
min 15
14.4.3
Minimum burn - up time
min 3
14.5.1
Supervision time
0
14.5.2
Boiler output in the mode - SUPERVISION
kW 2
14.5.3
Work cycle time - SUPERVISION
sec 20
14.5.4
Burner fan power - SUPERVISION
ot/min 900
14.6.1
Minimum burner fan power
% 9
14.6.2
Maximum burner fan power
% 100
14.6.3
Minimum fan speed
ot/min 400
14.6.4
Maximum fan speed
ot/min 2850
14.6.5
Low fuel detection time
min 1
14.6.6
Min. flame value in case of lack of fuel
% 5
14.6.7
Fan factor (PID)
% 30
14.6.8
Integer time constant
10
14.7
Thermostat selection
OFF
14.8
Minimum boiler temperature
°C 60
14.9
Maximum boiler temperature
°C 80
14.10
Boiler cooling temperature
°C 88
14.11
Backup boiler
0
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Pellet 30 Automatic Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Pellet 30 Automatic Plus in the language / languages: English as an attachment in your email.

The manual is 0.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK Pellet 30 Automatic Plus

ATTACK Pellet 30 Automatic Plus User Manual - German - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info