Alarms
Boiler's alarms
If the system WIFI modem - APP - Opentherm
termostat is working, the APP will show the sym-
bol on the side drop-down menu. By clicking
it, the alarm code "E…" will show, with a short de-
scripon and some instrucons.
On the boiler's handbook you'll nd a dedicat-
ed paragraph and a table that lists the possible
alarms and relevant, more detailed instrucons.
We suggest you to read it and to call the Assis-
tance Service whenever you have diculty solv-
ing the problem with the procedures reserved for
the User.
Note: as in all cases of malfunconing of any
device, the alarms provide an indicaon of
the most probable cause (to be invesgated
rst) but not exclusive of other problems, to
be xed by the Technician.
Kit-related alarms: E91 - E94
In case of failure of the system WIFI modem -
APP - Opentherm termostat, the APP will show
the symbol on the side drop-down menu.
By clicking it, one of the alarms listed below will
show, with a short descripon and some instruc-
ons.
E91 This alarm showing on the APP can be
triggered by dierent causes. Please, look
at the boiler's display and read the alarm
code shown on it:
if the alarm E91 is present on boiler's dis-
play too, the problem is relevant to the sys-
tem pressure transducer in the boiler;
if the boiler displays E31, the electrical link
between the boiler and the WIFI modem
could be faulty (interrupted or subject to
noise); see also "Electrical connecons" on
page 14
E94 This alarm showing on the APP can be
triggered by dierent causes. Please, look
at the boiler's display and read the alarm
code shown on it:
if no error code is displayed on the boiler,
the problem is probably located on the link
(interrupted or subject to noise) between
the WIFI modem and the Opentherm ter-
mostat (see also "Electrical connecons"
on page 14). In case of interrupon, the
Remote Control's display should be o;
if E31 appears on the boiler display, there is
a problem with the electrical connecons
between the boiler, WIFI modem and/or
Opentherm termostat (see also "Electrical
connecons" on page 14).
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK OT81 WIFI modem at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK OT81 WIFI modem in the language / languages: English as an attachment in your email.

The manual is 3.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info