810550
18
Zoom out
Zoom in
Previous page
1/28
Next page
18 |
TECHNICAL DATA
ATTACK boiler type Unit 9 12 15 20 25 30 35 40 45 50
Nominal output EKO, KLV, P kW
9 121520253035404549,9
Nominal input EKO, KLV, P kW
9,9 13,2 16,5 22 27,5 33 38,5 44 49,5 55
Number of elements pc
2 3 4567
Adjustable output PLQ, KLQ kW
5–9 12–15 15–20 18–25 24–30 28–35 38–45 42–49,9
Modulable output E, EZ kW
5–9 10–18 16–25 25–35 3045 33–49,9
Adjustable input PLQ, KLQ kW
5,5–9,9 13,2–16,5 16,5–22 19,8–24,5 26,4–33 30,8–38,5 41,8–49,5 46,2–55
Modulable input E, EZ kW
5,59,9 11–16,5 17,6–24,5 27,5–38,5 3349,5 36,3–55
Gas pressure in front of the boiler mbar
20
Diameter of nozzles mm
2,5 2,5 2,5 2,7 2,5 2,7 2,7 2,5 2,7 2,5
Pressure to nozzles – EKO, PLQ,
KLV, KLQ, P kPa
0,8–1,4 0,95 0,7–1,05 0,8–1,2 0,8–1,35 1–1,35 0,7–1,15 1,35 0,85–1,15 0,85–1,25
Pressure to nozzles – E, EZ kPa
0,8–1,4 0,5–1,4 0,5–1,35 0,65–1,15 0,6–1,15 0,6–1,25
Fuel consumption by max. output
– EKO, PLQ, KLV, KLQ, P m3/h
1,06 1,4 1,76 2,35 2,94 3,5 4,12 4,7 5,3 5,85
Fuel consumption by max. output
– E, EZ
m3/h
1,06 2,13 2,94 4,12 5,3 5,85
Fuel consumption by min. output
– EKO, PLQ, KLV, KLQ, P m3/h
0,88 1,4 1,76 2,13 2,82 3,3 4,4 4,9
Fuel consumption by min. output
– E, EZ m3/h
0,88—1,17—1,88—2,94 3,5 3,8
Fuel Natural gas „G 20“
Natural gas connection DN 15 (Pass through nut 3/4")
Flue exhaust diameter mm 110 135 145 165 180
Volume of the cast iron body l 7 10 13,8 16,8 19,8 22,8
Max. pressure in heating system bar PMS = 4
Connection of heating – forced
circulation / natural circulation (S, P)
G 1" / 6/4"
Boiler weight kg 73 99 125 151 180 208
Power supply V / Hz ~ 230 / 50
Grade of protection IP 40
Temperature of the heating
water °C 40–90 / 0–90 (P)
Efficiency % 90
Flue gas flow g/s 14,4 20,5 28,9 37,2
Electrical input W 15
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK KLV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK KLV in the language / languages: English as an attachment in your email.

The manual is 1.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info