Introduction
Dear customer,
Thank you for your confidence and purchase of our product, the ATTACK floor standing cast iron gas
boiler with fluent electronic output regulation. We wish it serves you reliably for a long time. Please,
read this instruction for use carefully to ensure reliable and correct function of the boiler. The manual is
written with reference to the faultless operation of the boiler connected into the central heating system.
The conditions of correct operation of the boiler:
ychoice of a suitable boiler type and output
ycorrect commission
yreasonable operation
y regular technical maintenance
y reliable service
GENERAL DESCRIPTION
The latest types of the ATTACK cast iron gas boilers are marked as EKO, PLQ, KLQ, KLV, E, EZ, P.
These products achieve high level of the technical-economic parameters, comparable with the top
foreign products. Thanks to progressive design, with high efficiency and long life they attain very
low level of pollutants in the flue gas and therefore they considerably save the environment. In all
the modifications is used an automatic gas valve, enabling reliable, safe and economical operation
with minimum need for manipulation. The boilers are assembled from the control and regulation
elements from the top European manufacturers and cast iron bodies (consisting from 2, 3, 4, 5, 6,
7 elements). The ATTACK gas boilers are equipped with the high quality stainless steel burners. All
the ATTACK floor standing boilers are certified under the CE1015.
PURPOSE OF USE
The type line of EKO, KLV boilers is produced with the stable capacity of 9, 12, 15, 20, 25, 30, 35, 40,
45, 49,9 kW. The P type line is produced in the stable capacity of 9, 18, 25, 35, 45, 50 kW. The PLQ, KLQ
type ranges are produced in modulated capacity of 6–9, 12–15, 15–20, 18–25, 24–30, 28–35, 3845,
42–49,9 kW. The E and EZ boilers are produced with the automatically modulated output of 6–9,
1018, 16–25, 25–35, 33–49,9 kW. They are used for heating or central heating of family houses, flats,
shops and similar premises where the natural gas as fuel is used. The boiler is intended to operate
with the heating water of the maximum hydrostatic pressure of 0,4 MPa (4 bar) in line with the STN
07 7401 norm (it must not be acidic, i.e. the pH value must be higher than 7 and the carbonic hard-
ness must be low) and operating temperature up to 90°C with connection to the heating systems
with forced or natural flow (marked as S or P).
For the domestic hot water preparation there are the indirect heated floor standing hot water
tanks of the same design as the ATTACK floor standing gas boilers.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK KLQ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK KLQ in the language / languages: English as an attachment in your email.

The manual is 1.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info