810554
31
Zoom out
Zoom in
Previous page
1/36
Next page
31
dependent on the demand of regulation and the safety
traffic and heat systém.
The pump has antiblocking function. More detailed
information are stated in the chatter No. 1.7.4
Protection function of the boiler.
Time running out of the pump make possible to take
away heat accumulated in the boiler body in time of
switching off the boiler. The effect is decreasing of
losses, removing of temperature tops, reducing of stone
and elongation of boiler life time.
Time running out of the pump is preset from the
production facility according to the point 2.4.
The pump is protected against blocking in operation
mode Stand-by. (see the chapter Protection functions).
If the boiler is for longer time out of its operation
switched off, we recommend, we recommend you to
switch on the boiler sometimes, minimally 1x per month
(see the chapter protection of function).
Electric data of the pump
P1 - pump input
I - electric current
4. Termination of operation
Concerning termination of boiler operation carry out it
by switching off the switcher in the lower part of the
boiler, by switching off the main switcher on the
electric supply feeding.
Service repairs see below mentioned instructions:
Disconnect boiler from electric supply
feeding by main switcher and contact
your service man!
Breakdowns of the boiler have to be
repair only by professional person!
Attention!
There is threat of casualty by electric
current!
5. Maintenance
Regular maintenance helps you to eliminate possible
defects. We recommend you to carry out complete
maintenance 1 time per year before starting heating
system. It is not allowed the taking off the cover. The user
is able to clean surface of the cover with detergents and
control operation modes or fill heating water to the system
checked by water pressure dawn according to the value on
the thermomanometer.
The service man during the regular control and
maintenance carry out tightening of all electric
connection, control tightness of all connection and control
quantity of water in the heating system, clean the water
filter, pump, control 3-ways valve control and switching
relay including starting function of the boiler.
Well, also the control of all safety and switching elements
will be carry out by heating operation and right function of
heating elements.
6. Full delivery
The electric boiler is delivered assembled
Full delivery of electric boiler consists of:
electric boiler assembled,
instruction manual,
guarantee card,
bushing,
deaerate valve,
bonding of switch board to electric supply connection
1 x 230 V.
Accessories whose are not part of the full
delivery:
conductors for supply connection of boiler and three
ways valve (in case that you have installed the storage
water tank) and for connection of the room thermostat
fixing set.
Module TUV.
Module GSM.
7. Transport and warehousing
The boiler is protected by its packaging during
warehousing and transport. It is necessary to eliminate
effects of magnetic and other influences on the
packaging.
It is necessary to eliminate concussions and to avoid
slighting out the boiler from the packaging.
Manipulate with the boiler and put it into position
according instruction marked on the packaging.
Regarding warehousing is necessary to assure standard
warehousing conditions (no aggressive environment
without dust, temperature from C to 50° C, humidity
to 75 %, no expose to biological influences, shocks and
vibration).
I 1/1(A) P1(W) Mpa
Min 0,05 4
Max 0,52 52 0.3
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Electric Excellent at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Electric Excellent in the language / languages: English as an attachment in your email.

The manual is 3.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info