810554
4
Zoom out
Zoom in
Previous page
1/36
Next page
4
product will serve you good and for long time. It is
necessary for you to study whole instruction manual and
hold all the principles. The declaration of conformity was
issued by the producer according to directives
2004/108/EC, 2006/95/EC,
Basic features
®
Boilers ATTACK are electric, using water for heating. It
is electric wall-hung appliance determined for heating
of family houses or flaks with heat loss to 22,5 kW.
The boiler could be used for heating of service utility
water (sanitary water) through storage water tank.
The boiler could be remote controlled by GSM.
Advantages of your boiler
SIMPLE CONTROL – you new boiler is in operation
automatically. After boiler professional putting into
operation is not necessary any additional setting. The
boiler will adapt to conditions of your heating system
DIMENSIONS your new boiler is really small regarding
its dimensions. You can place it anywhere where is
impossible to place another type of boilers.
REMINDER!
Your new boiler is not stay alone to be useful for your
comfort, use good outside insulation of your flat or your
house, use the room thermostat for economical
consumption of electric energy.
ATTACK, s.r.o
1. General information
1.1 Description and use
The wall hung electric boiler ELECTRA EXCELLENT is
convenient for heating in heating systems with forced
circle and for heating of service utility water (sanitary
water).
The heating of heating water takes place in a boiler drum
by means of one (EXCELLENT 08), two (EXCELLENT 15)
or three (EXCELLENT 24) heaters of a power output of
4,5 kW, 6 kW or 7,5 kW. Each heater consists of three
heating rods of a power output of 1,5 kW, 2 kW or 2,5 kW
each. Heating operation is controlled by control unit with
PID regulation. PID regulation assures high efficient
operation due to minimalizing of heating water
temperature overshoots over temperature setting. This
regulation saves also your energy consumption. The
boiler could be regulated by the room thermostat and it
also able to heat sanitary water in an independent storage
water tank connected through with 3-ways motoric valve.
1.2 Advantages of boiler
small dimensions, modern design
high efficiency 99 %
silent operation
information on the display
mode relay independent to the control unit cost
saving regarding replacement
step less regulation of boiler output with continuous
switching on/off heating elements economic
operation
rotation of heating elements ensuring elongation of
lifetime
possibility of using the boiler for under floor heating
system
breakdowns diagnostic system with display indication
information about heating system pressure thermo
manometer
operation mode Stand-by ensuring termination of
boiler operation with all protective functions:
protective functions:
antifreeze
deblocking
against overheating
against pressure lost
pump running out regulated by time or temperature
possibility of remote control with GSM
possibility of equitermic operation
possibility of connection with a storage water tank
possibility of a room thermostat connection
automatic deaerating
breakdowns statement memory
function back to factory setting.
1.3 Important instructions and
advices
Regarding installation, putting the boiler into operation
and maintenance it is necessary to observe instructions
according to concrete norms and regulations and
instructions from the producer. It is also necessary for you
to read carefully instruction manual and guarantee
conditions.
Control if the boiler in the box is completed regarding
accessories etc.
Control if the boiler type is in accordance with your
request for use.
The data stated on the type label has to be
compatible with conditions for boiler connection and
mounting.
It is not allowed for user to manipulate with parts
plumbed.
1.3.1 Installing, mounting of the boiler
Safety and economic operation of the boiler requests
a technical project made by authorized heating or
civil engineer for whole heating system.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Electric Excellent at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Electric Excellent in the language / languages: English as an attachment in your email.

The manual is 3.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info