1.5 Technical data
6
Boiler type
Electric parameters
Total electric input kW 7,5
Nominal heating output kW 7,5
Nominal current A 3x12 / 1x36
Voltage V 3x250/400 V+N+PE/50 HZ 1x250 V+N+PE/50 Hz
Nominal current max. A 3x16 / 1x40
Pump input W 60
Main circuit breaker A 3x16 / 1x40
Nominal current of control fuse A 0,315
Mechanical life time of relay - 1 000 000 cyklů
Electrical life time of relay 250 000 cycles, 16 A, 250 V
Width mm 370
Height mm 625
Depth mm 225
Boiler weight without water kg 19
Min. working overpressure of heating systém bar 0,4
Max. working overpressure of heating systém bar 3
Operation overpressure recommended kPa 100
Circle pump - CESAO 3
Maximal temperature of heating water °C 80
Water volume of whole boiler l 5,8
Environmental kind ČSN 332000-3 - normaly AA5, AB5
Efficiency by nominal output % 99
Supply cable CYKY 2
mm 3x2,5 / 1x6
Supply cable AYKY 2
mm 3x4 / 1x10
Expansion vessel l Not ineludet,volume read off ch.3.6
Surrounding temperature °C 0 ÷ 40
Warehousing and transport temperature °C -30 ÷ + 70
Electromagnetic temperature - EN 55014, EN 50082-1
Humidity % 0 ÷ 90 withouth condensation
Measuring accuracy % < 1
Accuracy of boiling water regulation °C ± 1
Regulation type - PI
Cascade - with cascade coutroller
Service plug - 6 PIN
Number of boilers in cascade max. - according cascade controller
Regulation
Remote control
Unit
Mechanical parameters
Environmental requests
Expanding temperature of thermostat
blocked, opened-closed systém °C 100
ATTACK ELECTRIC EASY 8
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Electric Easy at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Electric Easy in the language / languages: English as an attachment in your email.

The manual is 4.4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info