810551
12
Zoom out
Zoom in
Previous page
1/28
Next page
12 |
7. Turn the main switch into the on position. The gas flows into the burner where it is ignited.
8. Close the boiler front door.
Warning: ATTACK P boiler is a version of non-electrical installation.
STOP  PUTTING THE BOILER OUT OF OPERATION
For a short-time inactivity:
yswitch the main switch off. The valve closes because of losing the voltage and the gas supply is
interrupted
ythe flame of ignition burner still burns, the boiler is in a stand-by mode (EKO, PLQ, P)
yin the case of need, put the boiler into operation by switching the main switch on
yensure the heating system against frost damage
For a long-time inactivity:
yremove the boiler door
yturn the main switch off - the gas supply to the burners gets closed
yturn the control button of the valve in the direction of arrow and release, thus close the gas supply
to the ignition burner and other burners (EKO, PLQ, P)
yunplug the supply cable from electricity mains
yclose the manual gas valve on the supply pipe next to the boiler
yclose the boiler door
yensure the heating system against frost damage
Warning: The ATTACK P boiler is without electrical installation.
OPERATION CONTROL
The boiler is secured against dangerous operation states while working. However, it is not pos-
sible to prevent from the failures the cause of which is not included in the boiler mechanism. There-
fore it is necessary test the boiler once in three days after being started and to check the following:
ywhether the system is filled with water and there is no leakage
ywhether there is free approach of the outside air
ywhether the flue gas or gas cannot be smelled
ywhether there is no extra noise when burning the gas and no imperfect burning indicated by the
change of flame's blue color
The breakdowns detected must be reported to the service worker who put the boiler to
operation. If there is a gas leakage, the gas supply must be closed. The breakdowns found
must be removed immediately.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK E in the language / languages: English as an attachment in your email.

The manual is 1.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info