Oxygen sensor(Lambda probe)
Temperature sensor
Air flap V1 – V2, circuit pump, suction fan
Terminal 1: Sensor
Terminal 2: Sensor +
Terminal 3: Sensor warming
Terminal 4: Sensor warming
4-
wire flexi cable covered by
silicone with the section of
conductor of 0,75 mm
2
white = warming 12 V
black = + signal of sensor
grey = − signal of sensor
Terminal 1: Flue gas sensor F1 Pt100
Terminal 2: Flue gas sensor F1 Pt100
Terminal 3: Boiler sensor F2 Pt100
Terminal 4: Boiler sensor F2 Pt100
Terminal 5:
Terminal 6:
Values of the resistance:
T = 0 °C R = 100,0Ω
T = 20 °C R = 107,8Ω
T = 100 °C R = 138,5Ω
T = 200 °C R = 175,8Ω
Fix the flue gas sensor into the flue connection
by the bayonet flange!
Do not extend the connection conductors of
the sensors!
Treat the boiler sensor and the safety
thermostat sensor by a warm-water paste, put
it into the casing and fix by a spring!
Polarity is not important.
Use the 3
-
wire flexi cable with the
section of 0,75 mm
2
to connect the
circuit pump and the suction fan
C: STARTING CAPACITOR
Terminal 3: Connection
ŏ
Terminal 4: Connection 24V~
Terminal 5: Regulation signal sec. Y+ (0/2 – 10V)
Terminal 6: Regulation signal prim. Y+ (0/2 – 10V)
Terminal 12: L: Circuit pump
Terminal 13: N: Circuit pump
Terminal 14: PE: Circuit pump
Terminal 15: L: Suction fan
Terminal 16: N: Suction fan
Terminal 17: Free
Terminal 18: PE: Suction fan
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX in the language / languages: English as an attachment in your email.

The manual is 11.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK DPX

ATTACK DPX Additional guide - English - 21 pages

ATTACK DPX Additional guide - German - 21 pages

ATTACK DPX User Manual - German - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info