810510
22
Zoom out
Zoom in
Previous page
1/100
Next page
21
EN
6.1 TECHNICAL DESCRIPTION OF ATTACK DPX COMBI PELLET
6.1.1 OPERATING PRESCRIPTIONS
Boiler preparation for operation
Before starting the boiler, it is necessary to check that the system is filled with water, deaerated
and the pressure of heating water does not decrease. Make sure that the sensors of the boiler,
safety thermostat and manometer are placed in casings on the upper rear side of the boiler.
Check the tightness and construction of the flue connection. The boiler has to be operated in
line with the instructions given in this manual to achieve its good service. By boiler installation
you can underlay it for 10 mm to enable better flush by water and deaeration. Only an adult
trained person with completed elementary education can operate the boiler.
ATTENTION: By the first heat up it may come to condensation and leakage of the con-
densate – it is not a fault. There will be no more condensate after heating for a longer
time. In the case that the smaller wooden waste is being burned, it is necessary to check the flue
gas temperature which should not exceed 320 °C. Otherwise it could damage the fan. By the
gasification of wood it is normal that tar and condensates are created.
If the boiler has been out of order for a longer period, it is necessary to be more careful by start-
ing it again. It could come to the pump blockage, leakage of water from the system or to the
boiler freezing in the winter.
6.1.2 HEATING UP AND OPERATION
Before igniting the fuel, open the feeding door and push the pull rod of the heat up flap back to
the basic position until is the latch fixed (like when the door is closed, see the picture).
Position after the feeding door is open
Press backwards and downwards
Position after pressing backwards and downwards
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info