SmartControl
SmartControl is a versatile set of functions used to control the starting
and stopping of recording by automatic or external means. This section
outlines the different methods to start and stop recording. More
advanced external control using the Ronin serial port (marked LANC)
allows control from other devices such as serial control ports, using
computer applications, or API code-generating products. Atomos has a
document guide in its KnowledgeBase on how to use industry-adopted
protocols and the serial port for external control.
Ronin Start and Stop record control can be triggered by the
following methods:
1. Home Page Touch Screen
2. Monitor Page
3. HD-SDI Rolling Timecode trigger
4. HD-SDI Camera trigger
5. Via LANC for Sony and Canon Cameras
6. Via LANC serial port
1. Home page Touch Screen
By pressing Rec (Record)
2. From the Monitor Page
By pressing Rec (Record)
3. HD-SDI Rolling Time Code Trigger record
OFF DISABLED ENABLED
If HD-SDI timecode is selected and the camera is in Record run mode,
the user has the choice to start and stop recording remotely from the
moving HD-SDI timecode. To enable this simply arm the TC icon (see
above). When enabled the camera and the Ronin will start and stop
record simultaneously.
NOTE: Rolling timecode trigger is for use when the camera is in REC
RUN timecode mode only. Auto SDI flag triggers should be used for
Free Run timecode. Please be that aware not all cameras have Start/
Stop flags for triggering record, especially older cameras. In such cases
rolling trigger in REC RUN will need to be used to trigger recording
automatically at the same time as the camera starts recording.
4. HD-SDI Camera trigger record
The HD-SDI Camera trigger is manufacturer-specific, you will need to
select the appropriate manufacturer for your camera. There is a flag
within the SDI signal that lets the Ronin know the start/stop record has
been pressed on the camera; in turn this will trigger the Ronin to start/
stop recording at the same time as the camera.
You can use this mode with either Free-Run or Record-Run timecode
To enable this set Timecode to HD-SDI then set the camera manufacture
in the timecode menu
If both the Camera Trigger and Rolling Timecode Trigger are enabled this
can create multiple files, please ensure only one HD-SDI trigger is used.
5. via LANC for Sony and Canon Cameras
6. via the LANC serial port
Controlled by a third party computer or controller. For system and OEM
integration, contact support@atomos.com
Once you are recording you will see:
• The Rec button has now changed to Stop on the main screen
• Play button has been disabled
• The Record icon has changed to a stop icon on the monitor screen
• REC is in the top right corner of the monitor screen
Your files will be recorded to your drive with the unitname, scene
and shot you have setup.
To stop, press the stop button on the Ronin monitor or Trigger.
8. Monitoring and Recording
Atomos Ronin – User Manual Edition 2: November 2012 16
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atomos Ronin at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atomos Ronin in the language / languages: English as an attachment in your email.

The manual is 2.5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info