4-3
4.2.
THE GENERAL KNOWLEDGE OF RS485
4.2.1. BASIC CHARACTERISTIC OF RS485
RS485 is a half duplex communication bus whose impedance is
120Ω. Its carrying capacity is different because the different con-
nection interface, IC is 32-128 actual load (including master equip-
ment and slaves equipments).
4.2.2. RS485 TRANSMITTING DISTANCE
When 0.56 mm (24AWG) twisted pair line is used as the commu-
nication electric cable, there are different transmission distance
according to different Baud rate setting. Maximum transmission
distance and corresponding.
Baud rate
Maximum
distance
Baud rate
Maximum
distance
2400 BPS 1800 m 4800 BPS 1200 m
9600 BPS 800 m 19200 BPS 600 m
The max transmission distance would be shortened in conditions
as: when this product uses a slim communication electric cable
or the thermal speed dome is used in the environment with strong
electromagnetic interference or there are many equipments con-
nected to control bus, vice versa.
4.2.3. CONNECT MODE AND TERMINAL IMPEDANCE
The RS485 requires daisy-chain connection mode, and two 120Ω
terminal impedances should be connected. The mode was showed
as figure 4.1. Simplified connection mode shows in figure 4.2, make
sure that the distance of D can’t be more than 23 feet (7 meters).
FIGURE 4.1
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATN TASC Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATN TASC Series in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info