19. Laddomat 21
With its construction, Laddomat 21 replaces the tra-
ditional connection composed of individual parts.
It is composed of a cast-iron body, thermoregula-
tory valve, pump, non-return ap valve, ball valves
and thermometers. When the water temperature
reaches 78 °C, the thermoregulatory valve opens
the water supply from the storage tank. The con-
nection with Laddomat 21 is considerably easier
and therefore, we recommend it. A spare thermo-
cartridge of 72 ° C is supplied with the Laddomat
21 device. It is used for boilers over 32 kW.
OPERATION DATA
Max. operating pressure
0,25 MPa
Design pressure
0,25 MPa
Test over pressure
0,33 MPa
Hoghest operating temperature
100°C
WARNING - Laddomat 21 is designed only for boilers with output up to 75 kW (inclu-
sive). We recommend using it only with boilers with output up to 50 kW (inclusive).
20. Thermoregulatory valve
Thermoregulatory valve type ESBE, TV 60 °C is used with
solid fuel boilers. When the boiler water temperature reaches
+ 60 °C , the thermoregulatory valve opens and fluid from
the building heating circuit (2) enters the boiler circuit ( 3
1). Inlets 1 and 3 always remain open. This ensures that the
minimum temperature of the water returning to the boiler
is maintained. If need be, a thermoregulatory valve set to a
higher temperature (E.g. 7C) may be used.
Recommended sizes of the thermoregulatory valve TV 60°C.
For boilers: D14P, D21P, D25P .......................................................DN25, DN32









18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos D21P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos D21P in the language / languages: English as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info