3. Technical specifications
ATMOS boiler type D14P D21P D25P
Boiler output kW 4-14 4-19,5 7 -24
Heat-delivery area m
2
1,7 1,7 2
Fuel shaft volume dm
3
88 88 105
Filling opening dimensions mm 270x450 270x450 270x450
Prescribed chimney draught Pa 16 18 22
Max. working overpressure of water kPa 250 250 250
Boiler weight kg 231 231 254
Exhaust orifice diameter mm 152 152 152
Boiler height mm 1207 1207 1207
Boiler width mm 620 620 620
Boiler depth mm 768 768 868
Ingress protection of the electric part IP 20
El. power input - on startup
- in operation
W
522
42
522
42
522
42
Boiler efficiency % 90,3 90,2 90,2
Boiler class 3
Flue gas temperature at the nominal
output (pellets)
°C 127 147 151
Weight flow of flue gas at the nominal
output (pellets)
kg/s 0,011 0,015 0,018
Prescribed fuel
high-quality pellets with the diameter of 6 - 8 mm and the
calorific value of 15 - 18 MJ/kg
Average consumption of fuel - pellets
- at the nominal output
kg.h
-1
3,5 4,5 5,4
Water volume in the boiler l 56 56 62
Hydraulic loss of the boiler mbar 0,18 0,18 0,19
Minimum volume of the equalizing tank l 500 500 500
Mains voltage V/Hz 230/50
The prescribed minimum temperature of return water in operation is 65°C.
The prescribed operation temperature of the boiler is 80-90°C.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos D21P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos D21P in the language / languages: English as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info