ATMOS ACD01 – SERVICE MANUAL EN
9 Abbreviations used in the documentation
RED Reduced mode
HBR Hydraulic buffer
AF Outdoor sensor
IMP Pulse input
AF 2 Outdoor sensor 2
HK/HC Heating circuit
AGF Flue gas temperature sensor
KKPF Solid fuel boiler circulation pump
AGK Air flap
KP Boiler circulation pump
AGFmin Minimum flue gas temperature
KRLF Solar sensor of return water
AT Fixed buffer value (boiler type 3)
KSPF Solar sensor / bottom tank sensor
ATW-Temp.1
Flue gas temperature / Switching value for the
exhaust flap
KTmax Maximum boiler temperature
ATW1 SD Switching difference for the exhaust flap
KTmin Minimum boiler temperature
ATW Temp.2 Flue gas temperature / Fan control
KTpein Boiler pump enabling
BR1 Status of burner 1
KVLF Solar sensor
BRS/BRSP External boiler: oil/gas boiler
MIMO Mixing valve motor
BCP Boiler circulation pump
MK/MIX Mixed heating circuit
BS Buffer sensor (top)
MKP Mixed circuit pump
BS2 Buffer sensor (bottom)
P1 Time program 1
BULP Buffer charging pump
P2 Time program 2
BUS Data bus
P3 Time program 3
BZ1 Hour counter for burner 1
PF Buffer sensor (top)
BZ2 Hour counter for burner 2
PF1 Buffer sensor 1 (top)
CC Constant control
PF2 Buffer sensor 2 (bottom)
CHP Charging pump
PFsoll Fixed value of the buffer (boiler type 3)
CIR Circulation pump
PLP Tank zone valve
DHW Domestic hot water
PLV Tank valve
DHWP Hot water charging pump
PWF Parallel heating enabling
DKP Direct circuit pump
RBP Return supply pump
ECO Economic (reduced) mode
RED Reduced mode
EHP Electric heating of accum. tank
RG Room unit
ELH DHW electric heating (summer mode only)
RLP Return pipeline pump
ETUV DHW electric heating (controlled)
SBUS Buffer solar sensor
ERR Sensor Malfunction
SD I Switch-over differential I
FAN Fan (ON/OFF)
SD II Switch-over differential II
FKF Solid fuel boiler sensor
SDaus FSK switch-off differential
FPF Buffer sensor
SDbr Buffer switch-on differential (pellet or buffer mode)
FR Constant flow temp. control
SDein FSK switch-on difference
FSK Solid fuel boiler
Ta Fan running time in the manual mode (Burnout)
FSP Charging pump
Tb Fan running time in the manual mode (Start)
SDF Fan switching differential
VA Variable output (general)
SDpein Pump switch-on diff. (corresponds to KTpein)
VA/VO1 Variable output 1
SDplv Buffer valve switch-over differential
VA/VO2 Variable output 2
SF Buffer sensor
VE/VI Variable input (general)
SFB Solid fuel buffer sensor
VE/VI1 Variable input 1
SFD Solar dispersion
VE/VI2 Variable input 2
SFS Solid fuel boiler sensor
VE/VI3 Variable input 3
SFP Solid fuel charging pump
VF1 Sensor of mixed circuit 1
SLP Buffer charging pump
VF2 Sensor of mixed circuit 2
SLV Solar heating switch-over charging
WEZ General source of heat / Heater
SLVS Solar sensor of charging switch-over
WF/KF Boiler temperature
SOP Solar heating charging pump
ZKP Circulation pump
SPFS Solar heating flow pump
ZUP Charging pump
SPRS Solar heating return pipeline sensor
SSP Laminar flow pump
166


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos ACD01 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos ACD01 in the language / languages: English as an attachment in your email.

The manual is 7,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Atmos ACD01

Atmos ACD01 User Manual - German - 172 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info