810414
19
Zoom out
Zoom in
Previous page
1/72
Next page
Operation and Maintenance Manual - EN
EN
www.atmos.cz EN-19
13.
Connection diagram of the electronic unit AC07X with
AC07X-C additional module for DC40SPT, DC40GSP boilers
CAUTION - For the connection of the TS, TV, TK and TSV sensors the connection of
individual wires is not decisive (can be interchanged). TK and TSV sensors are built into
the boiler in the factory, TS and TV sensors are supplied with the boiler (included in the
packing). Under the AC07X electronic control unit system there is a potentiometer for setting
the display contrast; however, we do not recommend you to change its setting.
AC07X-C additional module is for DC40SPT, DC40GSP boilers designed to control pneumatic
cleaning system of the pellet burner via parameters S67 and S68 or for the special function.
rozšiøující moduly Ac10C a Ac10D k regulátoru Ac10A - pøipojovací schéma
1 2 3456
1234
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
2
34 9
10
1112 5
6
78 1
2
34
N
N
R7(NO)
R8(NC)
FAN1
FAN2
J1
J2
JP 1
R5
R6
not used
power supply
230V / 50Hz
2. ignitation spiral
[0.5 kW]
1. ignitation spiral
[0.5 kW]
[fuse on the boiler 6.3A/1500A]
[fusing by fuse on the boiler]
reserve with output
for burner connector
reserve number 2
special function
external conveyor
[fuse F0.8A1500A]
reserve number 2
special function
safety ther. of the burner
+ end limit switch
control thermostat of the boiler
burner fan
[fuse F1.0A1500A]
power supply
reserve number 5
special function
reserve number 6
special function
external screen AC06B
fan speed transducer
sensor TSV
(water, waste gas)
input
input
input
input
input
sensor TK
(boiler)
sensor TV
sensor TS
photocell
power supply NTP (+12V) - special function
(water, top of the tank)
( , bottom of the tank)waste gas
input
shielding (TS, TV, TK, TSV)
AC07X-C
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos A45SPT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos A45SPT in the language / languages: English as an attachment in your email.

The manual is 6.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info