9. Basic connection diagram of a D30P, D40P, D50P (D45P),
P30, P40, P50 boiler with an accumulation tank for burner
control on the basis of TS and TV sensors
INFO – The TV and TS sensors on the accumulation tank are connected directly to the
burner. The AD02 module is inserted under the instrument hood of the boiler and is con-
nected to the terminal board of the boiler (AD02 module - LA clamp), where it controls the
exhaust fan of the boiler.
Required accessories (not part of the burner): AD02 (AD03) module and two KTF 20 sensors – part
of the boiler delivery
System configuration of parameters: S6 = 4, S14 = 0, S15 = 2
(Reserve R – parameter S6 controls the boiler fan)
WA R N I NG – the AD02 module may be replaced by an AD03 module, whereas only the
required output is used (module AD03 – LA clamp)
The pump in the boiler circuit is controlled by the directly installed thermoregulator from the boiler
panel.
A45
odpad
outlet
Ts
Tv
Modul
AD02
termostat
thermostat
40°C - 60°C
MAX. 60°C
40 - 75°C
přívod
supply
2-6 bar
10-15°C
ventil / valve
TS131 – 3/4ZA
(WATTS STS20)
filtr
filter
obytné místnosti
haritable rooms
tlakoměr, přetlakový ventil,
odvzdušňovací ventil
pressure gauge, safety
valve, deaerator
tlaková
expansní
nádoba
pressure
expansion
vessel
ventil
valve
ventil
valve
bojler TUV
DHW boiler
ventil
valve
ventil
valve
ventil
valve
ventil
valve
A25
vyrovnávací nádrž
buffer tank
500 - 1000 l
odvzdušňovací ventil
deaerator
odtahový ventilátor
extraction fan
Laddomat 22
mísící ventil
mixing valve
čerpadlo
pump
ventil
valve
ventil
valve
filtr
filter
A45
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos A45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos A45 in the language / languages: English as an attachment in your email.

The manual is 5.37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Atmos A45

Atmos A45 User Manual - German - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info