613601
9
Zoom out
Zoom in
Previous page
1/24
Next page
ENGLISH (EN)
WARNINGS: This device is not intended for use by persons (including children) with physical, sensory
or mental disability, or by persons lacking experience or knowledge, unless they have received from a
person in charge of their safety adequate supervision or preliminary instructions on how to use the
device. Children should be supervised to ensure that they do not play with the appliance. This unit can
be used by children of not less than 8 years and people with reduced physical, sensory or mental
capabilities or without experience or knowledge if they are properly supervised or if the instructions for
using the device safely have been given and if the risks are taking into account. Children must not play
with the device. Cleaning and maintenance must not be done by children without supervision.
1. CAUTION! Heavy item, handle with care:
1.1 Install the appliance in a room which is protected from frost. If the appliance is damaged because
the safety device has been blocked, it is not covered by guarantee,
1.2 Make sure that the wall on which the appliance is mounted can support the weight of the
appliance when filled with water,
1.3 If the appliance is to be fitted in a room or location where the ambient temperature is higher than
35°C, provide sufficient ventilation,
1.4 When installed in a bathroom, do not install the appliance in volumes V0 and V1 (See fig.
,
p.3). If the water heater is to install above living space, fit a retaining tank with drain to the sewer
system. Place the water heater in a place with easy access,
1.5 If PER pipes are used, the installation of a thermostatic regulator on the output pipe of the device
is strongly recommended. It will be set according to the performance of the material used.
1.6 Installation of a vertical or horizontal wall mounted device: To allow the replacement of the
heating element leave a free space of 300mm between the tube ends and the wall or fixed
furniture.
1.7 Switch off the power before removing the cover, to avoid any risk of injury or electric shock.
1.8 The installation must be equipped, upstream of the appliance, with a bipolar cut-out device (fuse,
breaker switch) respecting local regulations (30 mA earth-leakage breaker).
1.9 If the supply cord is damaged, it must be replaced by a special cord or assembly available from
the manufacturer or the after sales service.
1.10 Mandatory installation of a safety device in a frost free location (or any other new device which
limits the tank pressure) to 7 or 9 bar (0.7 or 0.9 MPa) according to the nominal pressure, with a
size of ½ "or ¾" on the input of the water heater, respecting the local regulations (see table p.1),
1.11 Operate regularly the discharge of safety device to prevent scaling and check that it is not
blocked.
1.12 Hydraulic accessories should not be located between the safety valve and the cold water inlet. A
pressure reducer (not supplied) is required when the water supply pressure exceeds 5 bar (0,5
MPa) and will be fitted on the main supply.
1.13 Connect the safety device to an unpressurised outlet pipe in a frost free location, with a
continuous slope to evacuate water during heating up or draining the water heater.
1.14 The pipes used must support 10 bars (1 MPa) and 100 ° C.
1.15 To drain the device: Switch off the power and the supply of cold water, open the hot water
faucets and manipulate the safety valve. To drain under sink water heater disconnect the
hydraulic connections and return the device.
1.16 The products described in this manual are subject to changes at any time to be in
accordance with technology and standards. The devices comply with electromagnetic
directives 2004/108/EC and Low Voltage 2006/95/EC.
1.17 Do not dispose your water heater in the garbage, but hand it to a place assigned for this purpose
(collection point) where it can be recycled.
2. INSTALLATION
- Refer to the corresponding diagrams p.2 & 3 (see table on right):
- Make sure to keep free space of 300 mm below pipes for the exchange of
the heating element.
- For vertical installation of Ø 505 devices if the wall is not strong enough, an
optional ground support is available. Nevertheless, it is mandatory to fix the
unit to the wall with the top bracket to avoid tipping.
- For horizontal installation, the water connection tubes must always be in a
vertical position below the device.
3. HYDRAULIC CONNECTION
- It is necessary to clean the supply piping prior to the hydraulic connection. The connection to the hot water outlet is to be
carried out with a cast iron or steel sleeve or a dielectric connector, to avoid corrosion of the pipe (direct contact iron /
copper). The use of brass fittings is prohibited.
Diameter
Vertical
installation
Horizontal
installation
Ø255
See fig. &
Ø338
See fig. &
See fig.
Ø433
See fig. &
See fig.
Ø505
See fig.
1.16
bili u skladu s tehnologijom i standardima. u s direktivom 2004/108/EC
te direktivom za niski napon 2006/95/EC.
1.17
1. INSTALIRANJE
- idjeti tablicu desno):
-
- Za vertikalnu
- Za horizontalnu instalaciju, cijevi za vodu uvijek moraju biti postavljene
-
ako bi se izbjegla korozija na cijevi (izravan kontakt
Upotreba mesinganih sponica je zabranjena.
2.1 INSTALACIJA POD TLAKOM : Vidjeti fig.
, & , p.3.
vode bojlera, koji je u skladu sa standrardima (EN 1487 u Europi), s tlakom od 7 ili 9 bari (0,7 ili 0,9 MPa), u skladu s
nominalnim tlakom, promjera 1/2" ili 3/4" (tablica p.1).
2.2 INSTALACIJA BEZ TLAKA: Pogledati fig.
&
- OPREZ
nemojte ga upotrebljavati.
-
- Koristite
standardizirano kana
-
ili instalirati.
-
simbolom -
- Toplinski osig
A: Prekini dovod napona prije bilo kakve operacije B: Ukloni
C: Provjeri el D:
termostata.
4. POKRETANJE
- BOJLER BEZ VODE:
-
-
-
of the device, voda bi trebala kapati iz odvoda.
: Ukoliko
- OPREZ: Pr
A: Kamenac: Ukolnite
prvog grijanja . B:
promjer postane manji od 10mm. C:
nja, stegnite
ponovo ukoliko je potrebno. D:
-
Zamjenjivi Garancija
SAVJET KORISNIKU:
TH> 20 ° f ( >200 ppm ), preporuka je da se
pokretanje.
-
Promjer
Vertikalna
instalacija
Horizontal
na
instalacija
Ø255
See fig. &
Ø338
See fig. &
See fig.
Ø433
See fig. &
See fig.
Ø505
See fig.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atlantic Steatite at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atlantic Steatite in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 4,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info