817941
76
Zoom out
Zoom in
Previous page
1/80
Next page
- 76 -
Vooraleer de hydraulische module in te schakelen.
• Controleer de elektrische bekabeling
• Controleer de gasvulling van het koudemiddelcircuit.
Controleer de druk van het hydraulisch systeem (1-2
bar), controleer dan of de warmtepomp is ontlucht,
evenals de rest van de installatie.
"Checklist" om de inbedrijfstelling te ondersteunen
Vóór de start
OK Niet conform
Plaatsing (" Plaatsing", pagina 14)
Oppervlakte, volume en ventilatie van de ruimte.
Visuele controles Buitenunit ("Installatie buitenunit", pagina 15)
Lokalisatie en bevestigingen, condensafvoer.
Respecteer de afstanden tot obstakels.
Hydraulische controles Hydraulische module ("Installatie van de hydraulische module", pagina 18)
Aansluitingen van de leidingen, kleppen en pompen (Installatie verwarming, SWW).
Watervolume installatie (capaciteit van aangepast expansievat?).
Afwezigheid van lekken.
Druk primair circuit en ontlucht.
Aansluitingen en koelcontroles (" Koelaansluiting", pagina 26).
Controle van de koelkringen (afsluiting nageleefd, geen stof, geen vocht).
Aansluitingen tussen de eenheden (lengte leidingen, klemming naadloze verbindingen…).
Mechanische bescherming van de koelverbindingen
Installatie HD-manometers op gaslijn (dikke buis).
Vacuümtrekken verplicht.
Dichtheidstest met stikstof (~ 10 bar).
Opening kranen koelvloeistof op de buiteneenheid.
Vulling koelvloeistof van de hydraulische module en van de leidingen.
Vermeld op het etiket op de binneneenheid de hoeveelheid gas (fabriek + bijvulling) .
Visuele controles Buitenunit ("Buitenunit", pagina 72)
Elektrische voeding (230 V).
Bescherming door gekalibreerde stroomonderbreker.
Doorsnede van de kabel.
Aansluiting aarding.
Hydraulische module ("Hydraulische module", pagina 38).
Verbinding met buitenunit (L, N, aarding).
Aansluiting van verschillende sensoren (positionering en verbindingen).
Aansluiting richtkleppen (gekoppelde boiler en SWW) en circulatiepomp.
Voeding en bescherming van de elektrische bijverwarming.
Quick-start-procedure
Loria 6000 R32 / INSTALLATIE / 2256 - NL
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atlantic Loria at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atlantic Loria in the language / languages: Dutch as an attachment in your email.

The manual is 4.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Atlantic Loria

Atlantic Loria User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info