6. The device’s air dehumidification performance depends on
room design, room temperature and relative humidity of
the room air.
7. Drain the container when it is full. Then, reinsert the empty
water container so that the device can work again.
8. Tranport this device only in upright (vertical) position.
9. If the device does not work or if the operation is suddenly
interrupted for unknown reasons, ¨ see “Possible faults“.
10. When the air dehumidifier is in operation the compressor
generates waste heat and the room temperature slightly
increases. This is considered a normal process.
Control panel
1 ¨ ON/OFF button
2 ¨ Relative humidity (in %) or fault display
3 ¨ “Increase RH” button
4 ¨ Operating hour counter
5 ¨ “Reduce RH” button
6 ¨ Defrosting icon
7 ¨ “Fan ON” icon
8 ¨ “Water container full” icon
9 ¨ “Dehumidification mode” icon
Continuous display = dehumidfication is running
(compressor and fan on)
Flashing display = dehumidification is not
running (compressor off -
fan on)
Fault code
If the fault codes E3 – E4 – E5 are indicated in the “RH
display” ¨ see “Possible faults”.
Start-up
L An acoustic signal will sound if you connect the power
cable to an electrical socket.
A fault has occurred when this acoustic signal does not
sound. Check the power supply cable, the electrical
socket and the fuse.
Powering up
Press the button to switch on the power to the air
dehumidifier.
The display 2 ¨ “RH of air” indicates the factory-set humidity
of air of 60 %. After 5 seconds the display indicates the actual
humidity of air.
The “RH” display indicates the humidity of air in a range
between 30 % and 90 %.
Shutting down
Press the button again to switch off the power to the air
dehumidifier.
Setting the humidity value
Press the button (Increase the RH setting) or
(Reduce the RH setting) to set your desired relative humidity
of air.
If the set RH value is lower than 30 %, the device will
continuously dehumidify and the indicator 2 displays “CO”.
Hint: Normally, a relative humidity of air between 50 %
and 60 % is sufficient to have a convenient indoor
climate and to prevent condensation on structural
components and furnishing.
L If your desired RH value is lower than the actual RH by
3 %, the air dehumidifier will automatically start
(compressor). The
icon (dehumidification) is
continuously displayed.
If your desired RH value exceeds the actual RH by 3 %,
the air dehumidifier will automatically shut down
(compressor). The
icon (dehumidification) is flashing.
Automatic defroster
At a room temperature under 20 °C not only condensation
water is generated on the cold evaporator surface, but also
ice. This ice blocks the heat exchanger so that the air flow is
impeded. The built-in automatic defroster removes the ice
from the evaporator. This allows a dehumidification operation
down to a temperature of +5 °C.
During defrosting, the icon is displayed on the display, the
compressor continues to run, the fan is automatically stopped.
Once the defrosting process is finished the air dehumidifier
returns to the dehumidification mode and the
icon turns
off.
Operating hour counter
The air dehumidifier is equipped with an
operating hour counter.
The number of hours during which the device was in operation
in the past is displayed after the dehumidifier is turned on. The
amount of time during which the device remains on will be
added to the already elapsed time.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atika ALE 600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atika ALE 600 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 8,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info