EN 6
EXTRACTION SYSTEM AND ELECTRIC FLAP
Extractor hoods for mechanical ventilation systems
With central mechanical ventilation systems, the normal extraction
rate is often not high enough in the kitchen. ATAG has developed and
patented its own unique system. This system fits all of the leading
systems for central mechanical ventilation (CMV).
The system is a combination of two separate extraction systems:
mechanical ventilation and recirculation. On the one hand, optimum use
is made of the existing central mechanical ventilation system, and on
the other hand, a recirculation system is used to increase the rate of the
air being extracted.
1. CMV
2. Recirculation
1
2
1
2
The extractor hoods are fitted with a washable long-life charcoal filter,
and are quieter and more energy-efficient than conventional extraction
hoods. Almost all odours and vapours are eliminated even during
extended periods of cooking. Thanks to the recirculation system, the air
does not all disappear outside. That is because some of the extracted
air is returned into the kitchen after filtering. This means you use less
energy.
Motorless extractor hoods
ATAG also manufactures a complete range of motorless extractor
hoods, suitable for central mechanical ventilation systems with an
electrically operated flap for an hermetic seal. The electric flap opens
and closes within a few seconds. Once it is open or closed, the electric
motor is turned off which saves energy.
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG WS9111MR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG WS9111MR in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 4,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info