maintenance
Clean the extractor hood at least once a month. Clean the
grease filters at the same time.
The stainless steel on the outside of the hood can be cleaned
with soapy water and a damp cloth. The stainless steel will
regain its shine if you occasionally use a stainless steel care
product or polish. The polish imparts a dirt-resistant layer to
the stainless steel. Always clean the stainless steel in the
direction of polishing.
ATAG supplies cleaning and maintenance products for
extractor hoods.
For information on the availability of these, please contact
the consumer service department (for the telephone
numbers, please refer to the guarantee booklet).
Never use abrasive cleaning agents, green scouring pads,
other scourers or polishing cleaning products (such as liquid
scourers).
Never use caustic cleaning agents. These can cause
stainless steel to discolour.
solution
Pull the inner ring downwards
using a screwdriver (see
illustration).
NB: the glass is loose!
Pull the halogen lamp out of the
fitting and replace it with a
new 20 W halogen lamp. Use a
clean cloth to hold the new
lamp.
Change the discharge duct
(see installation instructions).
Phone the Service department.
Phone the Service department.
Phone the Service department.
cause
Lamp defective.
Discharge duct too long or has
too many bends.
Motor defective.
Motor or controls defective.
Connection lead defective.
fault
Lighting does not work.
Extractor hood makes a lot of
noise.
No extraction.
faults
Please check the following points which may solve the problem, before calling the service
department. Try to deal with the problem yourself first by checking the table below.
If the connection cable is damaged, it should be replaced by the service department of the
manufacturer or similarly qualified persons in order to prevent dangerous situations from arising.
NB: Disconnect the appliance from the mains before starting any repairs, preferably by removing the
plug from the socket or by setting the isolation switch to zero.
general
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG WS 9092 AM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG WS 9092 AM in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info