assembly
building-in dimensions wall hood
ø150/125
530
900
235
240
150
765-1125
min. 650
WG3/4V
ø150/125
700-1065
530
235
240
900
min. 650
60
WG3/4U
850-1210
min. 650
385
530
900
206
235
240
600
ø150/125
WG3/4K
WS9011MM
WS1211MM
min. 720 - max. 1080
WS9011NM
min. 745 - max. 1105
WS1211NM
installation (continued)
discharge
The discharge should not be connected to a duct which is
also used for other purposes under any circumstances.
Bear in mind any local regulations concerning the ventilation
of gas appliances.
The discharge may pass straight through the wall to the
outside, provided that the wall opening is protected - by
means of a grating - against rain, leaves, and the like getting
in. The passage of the discharge may not be restricted by
the wall grating by more than 20%.
We advise the use of as large a discharge duct as possible.
A duct with a smaller diameter will have a low extraction
capacity and produce higher noise levels.
Bends produce resistance. Make sure that the duct has a
smooth run and has as few bends as possible. Draw the
flexible pipe out as far as possible.
Before starting to drill, check that there are no installed
pipes present.
The discharge stump has a diameter of 150 mm. It is best if
the discharge pipe also has this diameter.
A reducing piece (150 mm to 125 mm) is supplied with the
appliance for connection to a 125 mm discharge pipe.
transport protection device
The cooker hood comes with a transport protection device
that has to be removed before installation. Remove the 4
screws at the rear of the motor module (see fig.) and detach
the motor module from the cooker hood. Observe
the assembly instructions on the following pages.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG WS 9011 N M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG WS 9011 N M in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info