121828
35
Zoom out
Zoom in
Previous page
1/37
Next page
GB 13
installation
general
GB 12
installation
general
the discharge
The discharge may under no circumstances be connected to
a duct that is also used for other purposes. Bear in mind the
local regulations concerning the ventilation of gas appliances.
The discharge may pass straight through the wall to the
outside, provided that the wall opening is protected against
the entry of rain, leaves and the like by a grating. The
passage of the discharge may not be restricted by more than
20% by the wall grating.
We advise the use of as large a discharge duct as possible.
A duct with a smaller diameter will have a low extraction
capacity and produce higher noise levels.
Bends produce resistance. Make sure that the duct has a
smooth run and has as few bends as possible. Draw the
flexible pipe out as far as possible. Before starting to drill,
check that there are no installation pipes (for gas, water, etc.)
present.
The discharge stump has a diameter of 125 mm. It is best if
the discharge pipe also has this diameter.
electrical connection
The plug should be accessible after the extractor hood is
fitted or it should be possible to disconnect the extractor
hood from the mains by means of a bipolar switch with a
contact gap of 3 mm.
When making the electrical connections, take care that the
voltage and frequency correspond to the values given on the
data plate.
If the connection cable becomes damaged, it should be
replaced by the manufacturer’s service department or by a
person with equivalent qualifications, in order to prevent
dangerous situations from arising.
safety
Attention: Make sure that there is a sufficient supply of
fresh air, if an extractor hood and a heat source (e.g. gas
cooker) that both consume air from the same room, are
switched on at the same time. The maximum permitted
underpressure is 4 Pa.
building-in dimensions
125
600
132
500
61
125
700
132
500
61
WO60..; WCA..; WMA..; WMB..; WO70..
WMC..; WMD..
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG WO 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG WO 60 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info