11
installation island hood
The key dimensions are indicated on page 9.
Set the height of the telescopic pipe within
the allowable range.
It is advisable to suspend the hood with the
help of an assembly lift. If there is no lift
present, it is advisable to carry out the
mounting with more than one person.
Position the discharge and the electrical
connection in such a way that it will be easy
to hook up the hood.
marking
- Mark the holes to be drilled on the ceiling
by means of the stencil.
- Drill the holes ( 4 x 10 mm).
placing the upper telescopic pipe
- Fix the plugs and the studs to the ceiling.
Screw the studs 20 mm into the plugs in
the ceiling.
- Put the top telescopic pipe over the studs.
Screw down the washers and the nuts.
determing the length
- Slide the lower telescopic pipe over the
motor frame of the hood and slide both
pipe and frame over the already-fitted
upper telescopic pipe.
- Determine the length of the telescopic
pipe. Remember the minimum height
above the hob.
- Mark the drill holes and slide the two
sections apart again.
- Drill the fixing holes (6.0 mm) at the side of
the upper telescopic pipe using the drill
bit supplied. Deburr the holes.
assembling the extractor hood
- Attach the connecting cable and
discharge hose from the inside (does not
apply to recirculation hoods). Make sure
the connecting cable is not pinched or
folded.
- Make the necessary plug-and socket
connections (to feed the external motor).
- Slide the hood over the upper telescopic
pipe. Secure it with the 4 screws.
10
installation wall hood
The key dimensions are indicated on page 9.
Set the height of the telescopic pipe within
the allowable range.
Position the discharge and the electrical
connection in such a way that it will be easy
to hook up the hood.
marking and mounting attachment
frame
- Draw a centre line on the wall (middle of
the hood).
- Place the fastening clip against the wall
so that it rests against the ceiling. The
arrow on the flanged rim indicates the
middle of the cooker hood. Mark the
attachment holes to be drilled.
- Drill the holes (8 mm).
- Insert the plugs and fasten the mounting
plate to the wall.
marking and assembling the hood
- Mark the holes to be drilled on the wall
by means of the stencil and drill the
holes.
- Insert plugs. Twist two nuts in the
opposite direction on the ends of the
studs and twist the studs about 20 mm
into the wall. Remove the nuts.
- Position the hood on the bolts. Fasten
washers and nuts and adjust the hood.
- Attach the connecting cable and
discharge hose from the inside (does not
apply to recirculation hoods). Make sure
the connecting cable is not pinched or
folded.
- Make the necessary plug and socket
connections.
hanging the telescopic pipe
- Push the flanged rim of the upper
telescopic pipe from the bottom in
between the fastening clip and push the
telescopic pipe up against the ceiling (the
telescopic pipe fixes itself).
- Bend the sides of the lower telescopic
pipe a little bit towards the outside and
clasp it over the upper telescopic pipe.
Push the lower telescopic pipe
downwards until it connects up the hood.