Installation
819*- 872
559
680-760**
52
193
442
573
596
131-186
50
30-94
1198
700
It is important that you read through and follow the instructions and
directions below. Conduct installation and connection in accordance
with the separate installation instructions.
Safety instructions
Connections to electricity, water and drainage must be performed
by a qualified professional.
Always follow applicable regulations for water, drainage and
electricity.
Take care during installation! Wear protective gloves! There must
always be two people!
Place a drip tray on the floor beneath the dishwasher to prevent
damage from any water leaks.
Before screwing the dishwasher into place, test the dishwasher by
running the Rinse and hold programme. Check that the dishwasher
fills with water and drains. Check also that none of the connections
leak.
WARNING!
Turn off the water supply when installing the dishwasher!
The plug must be disconnected or power to the socket turned off
while the work is carried out!
Setup
The recess and connection dimensions are included in the separate
installation instructions. Check that all dimensions are correct before
starting the installation. Note that the height of the cover door can
be adjusted to match other fittings.
Make sure the area on which the dishwasher is to be installed is
firm. Adjust the adjustable feet so that the dishwasher is level.
Tighten the lock nuts.
Drainage connection
See the separate installation instructions for necessary information.
This dishwasher is suitable for installing in a raised recess (to attain
an ergonomic working height). This means that the dishwasher can be
placed so that the drainage hose runs to a lower level than the bottom
of the dishwasher, such as by routing it directly to a floor drain. The
dishwasher is fitted with an integrated anti-siphon device to prevent
the machine from being emptied of water during the wash cycle.
The drainage hose can also be connected to a connection nipple on
the sink unit's water trap. The connection nipple must have an internal
diameter of at least 14 mm.
The drainage hose may be extended by a maximum of 2.5 m (the total
length of the drainage hose must not exceed 4.5 m). Any joins and
connecting pipes must have an internal diameter of at least 14 mm.
However, the drainage hose should ideally be replaced with a new
hose without joins.
No part of the drainage hose may be more than 950 mm above the
bottom of the dishwasher.
Ensure that the drainage hose has no kinks.
Connection to water supply
Use only the inlet hose supplied with the dishwasher. Do not re-use
old or other spare hoses.
The supply pipe must be fitted with a water tap (stopcock). The water
tap must be easily accessible, so that the water can be shut off if the
dishwasher has to be moved.
Once the installation is complete, turn on the water tap and allow the
pressure to settle for a while. Check that all connections are watertight.
Connection to cold water supply
Connect the dishwasher to the cold water supply if the building is
heated using oil, electricity or gas.
Connection to hot water supply
Connect the dishwasher to the hot water supply (max. 70 °C) if the
building is heated using an energy-efficient means such as district
20
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG VA7015QT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG VA7015QT in the language / languages: English as an attachment in your email.

The manual is 4,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG VA7015QT

ATAG VA7015QT Installation Guide - English, German - 2 pages

ATAG VA7015QT User Manual - German - 24 pages

ATAG VA7015QT Additional guide - Dutch - 2 pages

ATAG VA7015QT Installation Guide - Dutch - 2 pages

ATAG VA7015QT User Manual - Dutch - 24 pages

ATAG VA7015QT Installation Guide - French - 2 pages

ATAG VA7015QT User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info