OperatinginstructionsATAGQ-Series
Selection
Type of installation
Flow water
temperature
01
Radiators; air heating; convectors 85°C
02
Radiators with large surface areas or under floor heating as
additional heating
70°C
03
Under floor heating with radiators as additional heating 60°C
04
full under floor heating 50°C
= factory setting
Adjusting the type of installation
Theboilerisdesignedin sucha waythat itwill
adjust itself automatically to what is necessary
foranormalheatingsystem.Insomecasesthe
installationmayhaveconvectorsorcompleteun-
deroorheating.
Onecaneasilychooseheatinginstallationadjust-
mentsappropriateforthesystemsuchasmaxi-
mumwater-owtemperatureorforthewarmingup
oftheinstallationafteranightperiod.Adjustment
goesasfollows:
- Press(fromtheTechnical)readingtheMode
keyonce;
- PresstheStepkeytwice;
The display will show 2 01.
- Press the + or the - key to alter thetypeof
installationaccordingtothetablebelow;
- PresstheStorekeytoconrmthesetting;
The display will ash once.
- PresstheModekeyonce;
The display will show StbY for a short while
and will return to the Technical reading.
+
Store
Mode
Step
Reset
-
When a type of installation has been chosen with a low water-ow temperature it
is possible that in case of a severe winter period the temperature of the heating
system will need to be increased slightly. In such situations the installation choice
may need to be changed, so that a higher ow temperature can be chosen. This
adjustment would normally be carried out by your installer during the installation
and commissioning.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG Q51C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG Q51C in the language / languages: English as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG Q51C

ATAG Q51C User Manual - German - 16 pages

ATAG Q51C Manual - Dutch - 2 pages

ATAG Q51C Installation Guide - Dutch - 48 pages

ATAG Q51C User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info