1/86
Next page
Page GB-30
2200..00
NNIIGGHHTT
PPAARRAAMMEETTEERR 0011
m
MMOO
Parameter 1 - Domestic hot water night tempe-
rature
Setting range: 10.0 °C up to the required hot water temperature
Factory setting: 20 °C
Parameter 2 - Legionella protection - day
Setting range: OFF, Mo to Su, all days
Factory setting: Mo
DDAAYY
This parameter determines the magnitude of the required
domestic hot water temperature outside the hot water
standby times as well as in operational mode ABSENT for the
duration of the absence.
The legionella protection is a prevention against legionella
germination in the tank and is activated on the selected weekday
(Mo-Su) or every day at 2.00 am (factorysetting). If the hot-water
temperature should drop below 65 °C, the tank is reloaded. With
the setting OFF this function is not in effect.
°C
DDHHWW
DDHHWW
m
DHW
Note: Only accessible with code 1234.
This level includes the necessary parameters to adjust the dome-
stic hot-water economy temperature and the legionella protec-
tion.
Entry: see level synoptic page 14-15
Exit: Button
¢¢
or automatically after approx. 60
seconds
Change: Accept selected flashing parameter by pressing
the rotary pushbutton. Then change the parame-
ter value and accept by pressing the rotary push-
button again.
Application: Support temperature in the DHW-tank to avoid
cooling down
Note: This parameter, if using a DHW-thermostat
instead of a sensor, is skipped!
Note: Other legionella protection times can
only be set by the heating specialist.
Important: Danger of scalding! Use thermostatic mixing
valve on DHW tank outlet!
Entry:
next parameter
PPAARRAAMMEETTEERR 0022
NL
8A521100_GB.qxd 10.11.2004 12:05 Seite 30
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG MadQ-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG MadQ-2 in the language / languages: English, Dutch as an attachment in your email.

The manual is 19,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG MadQ-2

ATAG MadQ-2 Installation Guide - Dutch - 70 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info