675553
14
Zoom out
Zoom in
Previous page
1/32
Next page
u
Align the kitchen unit using a spirit level and marking square
and if necessary compensate with shims.
u
Ensure that the floor and walls of the unit are at right angles
to one another.
6 Unit door
-
One door is required for the kitchen unit.
-
The door must be minimum 16 mm and maximum 19 mm
thick.
-
There must be a gap of minimum 3 mm width between the
door and the unit door located above it (if one exists).
-
The width of the unit door depends on the style of the
kitchen and the gap size between the door panels of the
cabinet. Generally, there should remain a vertical gap of
3 mm between the unit doors.
-
If other cabinets are present, the top edge of the unit door
should be on a level with the doors of the adjoining units.
-
The unit door must be planar and mounted stress-free.
NOTICE
Risk of damage from over-heavy unit door!
If the unit door is too heavy, damage to the hinges and resulting
impairment of function cannot be excluded.
u
Before mounting the unit door, make sure that the door does
not exceed the approved unit door weight.
Appliance model Maximum cabinet
door weight (kg)
KD80102ADN 13
KD80122AFN 19
KD80140ADN, KD80140AFN,
KD80140BFN, KD80140CDN
21
KD80178AFN, KD80178CDN 26
7 Ventilation of the kitchen unit
Fig. 3
-
There must be an effective ventilation shaft of at least
200 cm
2
per appliance at the air inlet
Fig. 3 (A)
and outlet
Fig. 3 (B)
vent.
-
The principle applies that the larger the ventilation shaft, the
more energy-saving the operation of the appliance.
-
The depth of the ventilation shaft at the back of the cabinet
must be min. 40 mm.
Fig. 4
-
The upper ventilation shaft can either be positioned directly
above the appliance with an optional ventilation grille
Fig. 4 (C)
, close to the ceiling above the unit
Fig. 4 (D)
or as
an air outlet opening in a false ceiling
Fig. 4 (E)
.
Unit door
14 * Depending on model and options
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG KD80140ADN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG KD80140ADN in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG KD80140ADN

ATAG KD80140ADN User Manual - English, German - 32 pages

ATAG KD80140ADN Additional guide - Dutch - 1 pages

ATAG KD80140ADN User Manual - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info