GB 26
Electrical connectionINSTALLATION INSTRUCTIONS
3 phases with 1 zero connection (3 1N, 400 V ~ / 50 Hz):
The voltage between the phase and the zero is 230 V ~. º
The voltage between the two phases is 400 V ~.
Fit a connecting bridge between connecting points 4-4. Phase
3 carries no load. The groups must have fuses of at least 16 A
(3x). The core diameter of the connecting cable must be at least
2.5 mm
2
.
43 21
3L 1N a.c. 400V / 50 Hz
appliance
internal
generators
right
generators left
2 phases with 1 zero connection (2 1N, 400 V ~ / 50 Hz):
The voltage between the phase and the zero is 230 V ~. º
The voltage between the two phases is 400 V ~. If there is not
a voltage of 400 V ~ between the phases, two wires have
been taken from the same phase in the meter cupboard
and the hob must be connected with two neutral wires, as
indicated under 2 phases with 2 neutrals. Fit a connecting
bridge between connecting points 3-4. The groups must have
fuses of at least 16 A (2x). The core diameter of the connecting
cable must be at least 2.5 mm
2
.
43 21
2L 1N a.c. 400 V / 50 Hz
appliance
internal
generators
right
generators left
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG hi 6271 b at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG hi 6271 b in the language / languages: English, Dutch as an attachment in your email.

The manual is 3,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG hi 6271 b

ATAG hi 6271 b Installation Guide - English, German - 2 pages

ATAG hi 6271 b User Manual - German - 54 pages

ATAG hi 6271 b Installation Guide - Dutch - 2 pages

ATAG hi 6271 b Quick start guide - Dutch - 2 pages

ATAG hi 6271 b Installation Guide - Danish, French - 2 pages

ATAG hi 6271 b User Manual - French - 54 pages

ATAG hi 6271 b Installation Guide - Swedish, Norwegian - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info