467244
45
Zoom out
Zoom in
Previous page
1/72
Next page
INSTALLATIEHANDLEIDING ATAG ENERGION WARMTEPOMPEN
45
5.2.2
Blocking foutmeldingen - een blocking fout reset zich automatisch
wanneer de omstandigheid waardoor de foutmelding ontstond
verdwijnt.
Foutcode Constatering
Mogelijke
oorzaken Zie
tabel 5 bij nr.:
37
Geen communicatie met de watchdog processor
25
38
Fasen zijn in de verkeerde volgorde aangesloten
18
39
Power aansluitingsfout. externe fase L2 en L3 niet aanwezig
of de compressor en/of het electrisch element zijn niet
aangesloten
15/19/20
41
Compressor is niet aangesloten
19/21
42
Verwarmingselement is niet aangesloten of de Triac is kapot
15
44
Temperatuurmeting referentie fout
25
45
Temperatuurmeting referentie fout
25
46
Temperatuurmeting referentie fout
25
47
Temperatuurmeting referentie fout
25
49
CH aanvoer temperatuur is te hoog (>90°C)
7/8/9/10/16/24
58
Net frequentie fout (frequentie is geen 50 Hz)
25
59
Bron-in temperatuur is te laag
4/12/13/14/23
60
Bron-uit temperatuur is te laag
23/43
65
Bron-uit sensor is niet aangesloten
1/2
73
Boiler sensor is niet aangesloten
1/2
74
CV aanvoer temperatuur sensor is niet aangesloten
1/2
75
Bron-in temperatuur sensor is niet aangesloten
1/2
76
CV retour temperatuur sensor is niet aangesloten
1/2
81
Bron-uit temperatuur sensor is kortgesloten
2
89
Boiler temperatuur sensor is kortgesloten
2
90
CV aanvoer temperatuur sensor is kortgesloten
2
91
Bron-in temperatuur sensor is kortgesloten
2
92
CV retour temperatuur sensor is kortgesloten
2
93
Maximale compressor druk schakelaar is niet aangesloten
16
94
Minimale compressor druk schakelaar is open
11/12/13/14/24/43
95
Minimale compressor druk schakelaar is niet aangesloten
5/6
96
CV aanvoer temperatuur is geen 3°C warmer dan de CV
retour temperatuur, 40 seconden na de start van de
compressor
3/7/8/9/10/23/24/43
97
Bron-uit temperatuur bis geen 2°C warmer dan de bron-in
temperatuur, 40 seconden na de start van de compressor
4/11/12/13/23/24/43
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG Energion 6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG Energion 6 in the language / languages: Dutch as an attachment in your email.

The manual is 2,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info